Loading ...
Loading ...
Loading ...
© 2021 United States Stove Company
15
REFUELLING
CAUTION:
THE HOPPER AND STOVE TOP WILL BE HOT
DURING OPERATION; THEREFORE, YOU
SHOULD ALWAYS USE SOME TYPE OF HAND
PROTECTION WHEN REFUELING YOUR STOVE.
DO NOT TOUCH THE HOT SURFACES OF THE
STOVE. EDUCATE ALL CHILDREN ON THE
DANGERS OF A HIGH-TEMPERATURE STOVE.
YOUNG CHILDREN SHOULD BE SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS THE
STOVE.
NEVER PLACE YOUR HAND NEAR THE AUGER
WHILE THE STOVE IS IN OPERATION.
WE RECOMMEND THAT YOU NOT LET THE
HOPPER DROP BELOW 1/4 FULL.
WARNING:
KEEP HOPPER LID CLOSED AT ALL TIMES
EXCEPT WHEN REFILLING.
DO NOT OVERFILL HOPPER.
TAMPER WARNING
This wood heater has a manufacturer-set minimum low
burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood heater in a manner inconsistent with operating
instructions in this manual.
SHUTDOWN PROCEDURE
WARNING:
NEVER SHUT DOWN THIS UNIT BY UNPLUGGING
IT FROM THE POWER SOURCE.
Turning your stove o is a matter of pressing the “POWER”
button on the display board. The green light will turn back
to red when the “POWER” button is pushed. The auger
motor will stop, and the blowers will continue to operate
until the internal firebox temperatures have fallen to a
preset level.
1. Your stove is equipped with a high temperature
thermodisc. This unit has a manual reset thermodisc.
This safety switch has two functions.
A. To recognize an overheat situation in the stove and
shut down the fuel feed or auger system.
B. In case of a malfunctioning convection blower, the
high-temperature thermodisc will automatically
shut down the auger, preventing the stove from
overheating.
NOTE: On some units, once tripped, like a circuit breaker,
the reset button will have to be pushed before restarting
your stove. On other units the thermodisc has no reset
button and will reset itself once the stove has cooled. The
manufacturer recommends that you call your dealer if
this occurs as this may indicate a more serious problem.
A service call may be required.
2. If the combustion blower fails, an air pressure switch
will automatically shut down the auger.
NOTE: Opening the stove door for more than 30 seconds
during operation will cause enough pressure change to
activate the air switch, shutting the fuel feed o. The stove
will shut down and show “E2” on the two digit display.
The stove has to fully shut down before restarting.
INTERIOR CHAMBERS
Burn Pot - Periodically remove and clean the burn pot
and the area inside the burn pot housing. In particular,
it is advisable to clean out the holes in the burn pot to
remove any build up that may prevent air from moving
through the burn pot freely.
Over time ash or dust may accumulate on the blades
of the circulation & exhaust fans. The fans should be
inspected, periodically, and if any accumulation is
present vacuumed clean as the ash or dust can impede
the fans performance. It is also possible that creosote
may accumulate in the exhaust fan therefore, this must
be brushed clean. The exhaust fan can be found behind
the left side panel (facing the front of the heater), the
circulation fan can be found behind the right side panel.
To access the igniter, remove the air inlet tube and cover
(2 screws). The auger motor is located in the center rear
of the unit. Note: When cleaning, take care not to damage
the fan blades.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac is
designed for ash removal. Some regular vacuum cleaner
(i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
OPERATION INSTRUCTIONS
Loading ...
Loading ...
Loading ...