Loading ...
Loading ...
Loading ...
© 2021 United States Stove Company
11
OPERATION INSTRUCTIONS
During start-up ignition must occur within 12 minutes
or the stove will error out and show E3.
During the start-up phase, the Mode key does not
function.
B. Heat Range Arrow Buttons
These buttons when pushed will set the pellet feed
rate, hence the heat output or heat range of your stove.
When using the hand-held remote this function can be
performed with the “Up/Down” buttons.
The levels of heat output will incrementally change on
the bar graph starting from heat range “1” to heat range
“5”.
CONTROL PANEL OVERVIEW
Turning the heater ON/OFF, as well as adjustments for
the fuel feed rate and room fan speed are performed by
pressing the appropriate button(s) on the control panel
which is located on the lower left-hand side of your heater.
ON/OFF
Pressing the “ON” button on the control panel will begin
the start-up sequence for the heater. Fuel will begin to
feed through the auger feed system then ignite after
approximately 5 minutes.
Pressing the “OFF” button on the control panel will cause
the heater to enter its shut-down sequence. The fuel feed
system will stop pulling fuel from the hopper and, once
the fire goes out and the heater cools down, the fans will
stop running.
HEAT RANGE
Pressing the “Heat Range” arrows, up or down, will adjust
the amount of fuel being delivered to the burnpot.
DRAFT FAN
The draft fan (exhaust) will come on as soon as the “ON”
button is pressed. The fan will automatically adjust its
speed in accordance to the heat range setting. However,
this speed can be manually operated by pressing the
“Draft Fan” arrows up or down. “Draft Fan” when pressed,
the display will show “Df-A, which is automatic. Press
the arrows again to adjust fan speed. When the heater
is in the manual mode, the optional thermostat will not
properly control the unit. When adjusting the Draft Fan
setting, try only 1 setting above or below the heat setting.
It is better to leave the stove in the automatic mode.
ROOM FAN
The room fan will come on once the unit has reached
operating temperature. By pressing the “Room Fan”
buttons, the display will show “Rf-A” which is automatic
or “Rf-1” through “Rf-9” for manual settings. In auto
mode, the room fan’s speed will automatically be adjusted
in accordance with the heat range setting. By pressing
the “Room Fan” up arrow, you can adjust the fan speed
setting up to “Rf-9”. The room fan must operate at a level
greater than or equal to the heat range setting.
AUX - USED TO RETURN THE STOVE TO THE
FACTORY SETTINGS
To return the stove to it’s original factory settings,
press and hold the AUX UP and AUX DOWN buttons
simultaneously for 3 seconds.
AUGER DELAY
The “Auger Delay” button can be used to pause rotation
of the Auger for approximately 1 minute. This can be
cancelled by pressing the “ON” button. The “Auger Delay”
is normally used only during the start up cycle to slow the
fuel delivery down during the initial ignition.
MODE
The “Mode” button is not used on this model.
During normal operation, the unit is constantly monitored
for problems. In the event of an error condition, the unit
will stop and an error will be displayed. See the list of
error codes found at the end of this manual.
Loading ...
Loading ...
Loading ...