Pleasant Hearth PH2200WS Large Wood Burning Stove 2,200 sq. ft.

User Manual - Page 10

For PH2200WS. Also, The document are for others Pleasant Hearth models: PH2200WS-B, HWS-2200, HWS-2200-B, PWS-2200-B, SWS-2200, SWS-2200-B, WSL-2200, WSL-2200-B, WS-2200, WS-2200-B, LWS-2200, GWS-2200, GWS-2200-B

PDF File Manual, 69 pages, Read Online | Download pdf file

PH2200WS photo
Loading ...
Loading ...
Loading ...
9
Solid Pack Chimney with Metal Supports as a Thimble
(Cont’d)
Chimney Height / Rise and Run
This product was designed for and tested on a 6 inch
(152mm) chimney, 14 to 16 feet (420-480cm) high,
(includes stove height) measured from the base of the
appliance. The further your stack height or diameter varies
from this configuration, the possibility of performance
problems exists. Chimney height may need to be increased
by 2% per each 1000 feet above sea level. It is not recom-
mended to use offsets or elbows at altitudes above 4000
feet above sea level or when there are other factors that
affect flue draft.
INSTALLING CHIMNEY COMPONENTS
Chimney Connector
Single wall connector or stove pipe.
This must be at least 24 gauge mild steel. The sections
must be attached to the appliance and to each other with
the crimped (male) end pointing toward the stove. All
joints, including the connection at the flue collar, should be
secured with sheet metal screws. Make sure to follow the
minimum clearances to combustibles. Where passage
through the wall, or partition of combustible construction
is desired in Canada, the installation shall conform to CAN/
CSA-B365.
Figure 7.2
Figure 8
WARNING
Asphyxiation Risk.
Do NOT connect this unit to a chimney flue servicing
another appliance.
• Do NOT connect to any air distributon duct or system.
May allow flue gases to enter the house.
WARNING
Fire Risk.
Follow Chimney Connector Manufacturer’s
Instructions for Proper Installation.
ONLY use connector:
• Within the room, between appliance and ceiling
or wall.
Connector shall NOT pass through:
• Attic or roof space
• Closet or similar concealed space
• Floor or ceiling
Maintain minimum clearances to combustibles
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with
this appli-ance. For assistance or additional information
consult a qualified installer, service agency or your dealer.
WARNING
Fire Risk.
Inspection of Chimney:
• Chimney must be in good condition.
• Meets minimum standard of NFPA 211
Factory-built chimney must be 6 inch (152mm) UL103HT.
Loading ...
Loading ...
Loading ...