Drain Valve:The drain valve is located
at the base of the air tank and is used
to drain condensation at the end of
each use.
Drain
Valve
Check Valve:
When the air
compressor is
operating, the
check valve is
"open", allowing
compressed air
to enter the air
tank. When the
air compressor
reaches "cut-
out" pressure, the check valve "clos-
es", allowing air pressure to remain
inside the air tank.
Pressure Release Valve: The pres-
sure release valve located on the side
of the pressure switch, is designed to
automatically release compressed air
from the compressor head and the
outlet tube when the air compressor
reaches "cut-out" pressure or is shut
off. The pressure release valve allows
the motor to restart freely. When the
motor stops running, air will be heard
escaping from this valve for a few sec-
onds. No air should be heard leaking
when the motor is running or after the
unit reaches "cut-out" pressure.
Reset
Release
Valve
Motor Overload Protector: This
motor has a manual thermal overload
protector. If the motor overheats for
any reason, the overload protector
will shut off the motor. The motor
must be allowed to cool down before
restarting. To restart:
1. Place the Auto/Off lever in the
"Off" position.
2. Allow the motor to cool.
3. Depress the red reset button on
the motor.
4. Place the Auto/Off lever in the
"Auto" postion to restart the
motor.
Air intake Filter (not shown): This
filter is designed to clean air coming
into the pump. This filter must always
be clean and ventilation openings free
from obstructions. See Maintenance.
HOW TO USE YOUR UNiT
How to Stop:
Set the Auto/Off lever to "Off".
Before Starting
Do not operate
this unit until you
read this instruction manual for
safety, operation and maintenance
instructions.
Break=in Procedure
_Risk of property
damage. Serious
damage may result if the following
break-in instructions are not
closely followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been replaced.
1. Make sure the Auto/Off lever is in
the "Off" position.
2. Check oil level in pump. See Oil
paragraph in the Maintenance
section for instructions.
3. Recheck all wiring. Make sure
wires are secure at all terminals
connections. Make sure all
contacts move freely and are not
obstructed.