Installation
www.bora.com
5 Installation
Observe all safety and warning information (see the
Safety section).
Follow the enclosed manufacturer’s information.
INFO The cooktop must not be installed above
cooling devices, dishwashers, stoves, baking
ovens, washing machines or driers.
INFO The contact surface of the worktops and wall
sealing strips must be made of a heat-resistant
material (up to approx. 100 °C).
INFO Worktop cut-outs must be moisture-sealed
using suitable means or, where necessary,
fitted with a thermal insulator.
INFO Control knobs have to be connected only to the
provided connections of the cooktop.
5.1 Checking the scope of delivery
Name Quantity
Control knob 2
Operating and installation instructions 1
Cooktop fixing screws 4
Height adjustment plate set 1
Cooktop 1
Cooktop mounting straps 4
Control knob cable 2
Automatic extraction system cable 1
Cleaning instructions for glass ceramic 1
Glass ceramic scraper 1
Tab. 5.1 Scope of delivery
Check the delivered items for damage and make sure
that everything has been received.
If there are any missing or damaged parts, please
notify BORA After Sales Service immediately.
Do not under any circumstances install parts which are
damaged.
Dispose of transport packaging in the proper manner
(see the Decommissioning and Disposal section).
5.2 Tool and aids
The following tools are required to correctly install the
cooktop:
Pencil
Measuring instrument
Standard or cordless drill with Forstner bit Ø 50 mm
Screwdriver/hexalobular wrench (torx) 20
Silicone sealant for sealing cutting surfaces
5.3 Assembly instructions
5.3.1 Safety clearances
Maintain the following safety clearances:
1
3
2
Fig. 5.1 Minimum clearances
[1] Minimum clearance of 50 mm at the back from the worktop
cut-out to the rear edge of the worktop.
[2] Minimum clearance of 300 mm from the left and right of the
worktop cut-out to the adjacent cabinet or wall.
[3] Minimum clearance of 600 mm between the worktop and
the wall unit.
5.3.2 Work surface and kitchen units
Create the worktop cut-out taking the specified cut-out
dimensions into account.
Make sure that the cutting surfaces of the worktops
are properly sealed.
Observe the instructions provided by the worktop
manufacturer.
Cross bars on the unit in the area of the worktop cut-
out may need to be removed.
A false floor underneath the cooktop with integrated
cooktop extractor is not needed.
If a cable protection shelf (false floor) is planned for
under the devices, this must be installed so as to be
removable for maintenance work.
The drawers and/or shelves in the floor unit must be
removable.