STEP3.Attacha3/4-inch,U.L-listed,
strainrelieftotheholebelowterminal
blockopening.Strainreliefshouldhave
atightfitwithdryercabinetandbeina
horizontalposition.Putthepowersupply
cordthroughthestrainrelief.
STEP4.Removethecenterterminal
blockscrew.Removetheneutralground-
ingwire(green/yellowwire)fromexternal
groundingscrew.
External ground
connector
/
Green/yellow wire
o! harness
Center silver-c01ored
terminal block screw
STEP 5. Connect neutral grounding wire
and the neutral wire (white) of power
supply cord under the center screw of
terminal block.
STEP 6. Connect the other two insulated
wires to outer terminal block screws.
STEP 7. Connect the green, grounding
wire from the power supply cord to the
external grounding conductor screw.
Tighten all terminal block screws firmly.
STEP 8. Tighten the strain relief screws.
STEP 9. Insert tab of terminal block
cover into slot of the dryer rear panel.
Secure cover with hold-down screw.
Proceed with Exhaust Installation.
See "CONNECT EXHAUST" on
page 19.
External
ground
connector
-\,
Centersilver-
coloredterminal
Whiteneutral
wire
Green wire
01power supply
cord or bare
copperwire
Neutral
grounding wire
(green/yellow)
3/4",EL-listed,
strain relief
4=Wire Connection with
Frame-Grounding Conductor