Daikin 1311441 LV Series 18000 BTU Single Zone Mini Split System

Service Manual - Page 358

For 1311441. Also, The document are for others Daikin models: FTXS30LVJU, FTXS36LVJU, RKS30LVJU, RKS36LVJU, FTXS09LVJU, FDXS09LVJU, FTXS12LVJU, FDXS12LVJU, FTXS15LVJU, FTXS18LVJU, FTXS30LVJU, RXS09LVJU, RXS12LVJU, RXS15LVJU, RXS18LVJU, RXS24LVJU, RXS30LVJU, RXS36LVJU

PDF File Manual, 414 pages, Read Online | Download pdf file

1311441 photo
Loading ...
Loading ...
Loading ...
SiUS091133 Outdoor Unit: RXS24LVJU
Removal Procedure 348
6.5 Removal of Coils / Thermistors
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the electronic
expansion valve coil.
1 Pull the electronic
expansion valve coil
out.
2. Remove the four-way
valve coil.
1 Remove the screw.
Electronic
expansion
valve coil
(R11159)
(R6457)
Loading ...
Loading ...
Loading ...