SiUS091133 Indoor Unit: FTXS15/18/24LVJU
Removal Procedure 200
2. Remove the
INTELLIGENT EYE
sensor PCB.
1
Unfasten the 2 hooks
on the right and then
the 2 hooks on the left.
Remove the
INTELLIGENT EYE
sensor ASSY.
2
Remove the sensor
from the shield plate.
When reassembling, set the
sensor at the position where it
“clicks”. Otherwise, the sensor is
not completely set.
Step
Procedure Points
(R9523)
Hook
Hook
INTELLIGENT EYE
sensor ASSY
(R9524)
(R9525)
Sensor Shield plate