Service Manual - Page 274

For 1311441. Also, The document are for others Daikin models: FTXS30LVJU, FTXS36LVJU, RKS30LVJU, RKS36LVJU, FTXS09LVJU, FDXS09LVJU, FTXS12LVJU, FDXS12LVJU, FTXS15LVJU, FTXS18LVJU, FTXS30LVJU, RXS09LVJU, RXS12LVJU, RXS15LVJU, RXS18LVJU, RXS24LVJU, RXS30LVJU, RXS36LVJU

Loading ...
Loading ...
Loading ...
SiUS091133 Outdoor Unit: RXS09/12LVJU
Removal Procedure 264
3. Remove the fan motor. Nut size: M6
1
Remove the nut of the
outdoor fan.
2
Remove the outdoor
fan.
When reassembling, align the
mark of the outdoor fan with
the D-cut section of the motor
shaft.
3
Release the outdoor
temperature thermistor.
Step
Procedure Points
Outdoor fan
(R16922)
10 mm
(0.39 inch)
(R16985)
D-cut
(R11828)
Outdoor temperature
thermistor
(R16986)
Loading ...
Loading ...
Loading ...