Pleasant Hearth PHZC42C 42" Circulating Vent-Free Zero Clearance Universal Gas Fireplace Firebox Only

USE AND CARE GUIDE - Page 8

For PHZC42C. Also, The document are for others Pleasant Hearth models: PHZC32C, PHZC36C, PHZC32F, PHZC36F, PHZC42F

PDF File Manual, 16 pages, Read Online | Download pdf file

PHZC42C photo
Loading ...
Loading ...
Loading ...
8
Minimum Clearances
Ensure that minimum clearances shown in Figures 4 through 8
are maintained. Left and right clearances are determined when
facing the front of the rebox.
Follow these instructions carefully to ensure safe installation.
Failure to follow these requirements may create a re hazard.
1. Sidewall clearances:
The clearance from the outside of the appliance to any combustible
wall should not be less than 9”. Figure 4 and Figure 6
2. Ceiling clearance:
The ceiling must be at least 42” from the top of the rebox opening.
Figure 4
3. Back wall clearance:
The appliance must have 1/4” MIN. clearance to a combustible back
wall.
4. Mantel clearances:
The canopy/hood supplied with the unit must be installed. If a
combustible mantel is installed, it must meet the clearance require-
ments as shown in Figure 5.
Figure 4 - Clearance to Combustible Surfaces
42" Minimum
Clearance to Ceiling
4
2
"
Mi
n
i
m
um
In
F
r
o
n
t
o
f
F
i
r
e
pl
a
c
e
9
"
Mi
n
i
m
u
m
C
l
e
a
r
a
nc
e
to
Si
d
e
W
a
l
l
s
9
"
Mi
n
i
m
um
C
l
e
a
r
a
nc
e
to
Si
de
W
a
l
l
s
Fig. - Clearance to Combustible Surfaces
Figure 5 - Mantle Clearances (Top)
Figure 6 - Mantle Leg Clearances
(Applicable for Both Sides)
Wall Stud
Drywall Board
Noncombustible
Facing Material
23"
21"
19"
16"
12"
12"
10"
8"
6"
2 1/2"
3/4" Maintain Clearance
Fig. - Mantle Clearances (Top)
2 1/2"
5"
7 1/2"
3 1/2"
6"
45°
Fig. - Mantle Leg Clearances
(Applicable for Both Sides)
Finished Wall
Wall Stud
Allowable Combustible
Material Area