Installation
www.bora.com
5.5 Installing the cooktop
INFO Clearance of one millimetre should be planned
between the built-in appliances.
INFO A clearance of two millimetres should be planned
around the built-in appliances.
INFO It is recommended to install a mounting rail
between adjacent cooktops (mounting rail PZMS
available as an accessory).
INFO Alternatively, the cooktop can be fitted rotated by
180°.
5.5.1 Installing the control knob in the floor
unit front panel
INFO Pre-drill the bore holes to prevent tearing out the
fixed front panel.
Fig. 5.7 Installed control knob and cooktop
≥40≥70
Ø50 ±0,5
370
80-140
Fig. 5.8 Drill template
5.4.2 Surface mounting
x
B ±2
≤ R5
≥ 74
(≥ 70)
516 ±2
≥ 700
Fig. 5.5 Cut-out dimensions for surface mounting
12
10 - 40
Fig. 5.6 Surface mounting cut-out
Cut-out dimensions when installing cooktops or cooktops
and the cooktop extractor next to each other:
Cooktops/cooktop extractor B in mm
1/0 346
1/1 457
2/1 828
3/2 1310
4/2 1681
Tab. 5.3 Cut-out dimensions for surface mounting of appliance
combinations