4
4.2 Press the remote control push button
to close the door. The door will not
move more than an inch (2.5 cm).
Test the Protector System
®
4.1 Open the door. Place an obstruction in
the path of the door.
The garage door opener will not close from a remote
control if the LED in either safety reversing sensor
is off (alerting you to the fact that the sensor is
misaligned or obstructed).
If the garage door opener closes the door when the
safety reversing sensor is obstructed (and the sensors
are no more than 6 inches [15 cm] above the floor),
call for a trained door systems technician.
4
3.1 With the door fully open, place a 1-1/2
inch (3.8 cm) board (or a 2x4 laid flat)
on the floor, centered under the garage
door.
Test the Safety Reversal System
3.2 Press the remote control push button
to close the door. The door MUST
reverse when it makes contact with the
board.
If the door stops but does not reverse:
1. Repeat Program the Travel (see Adjustment Step
1);
2. Repeat the Safety Reversal test.
If the test continues to fail, call a trained door systems
technician.
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing
garage door.
Safety reversal system MUST be tested every
month.
After ANY adjustments are made, the safety
reversal system MUST be tested. Door MUST
reverse on contact with 1-1/2" high (3.8 cm)
object (or 2x4 laid flat) on the floor.
3
Without a properly installed safety reversing
sensor, persons (particularly small children) could
be SERIOUSLY INJURED or KILLED by a closing
garage door.
Loading ...