Burner and nozzle characteristics tables
1 Natural gas G20 - 20 mbar SR R UR2 int. UR2 ext.
Rated heating capacity (kW)
1.80 3.0 0.9 3.30
Nozzle diameter (1/100 mm)
97 120 70 128
Pre-chamber (printed on nozzle)
ZH9H1F3
Reduced flow rate (W)
500 800 400 1200
2 Natural gas G20 - 25 mbar SR R UR2 int. UR2 ext.
Rated heating capacity (kW)
1.80 3.0 0.8 3.4
Nozzle diameter (1/100 mm)
94 110 65 130
Pre-chamber (printed on nozzle)
ZH8H1H3
Reduced flow rate (W)
500 800 400 1200
3 Natural gas G25/G25.3 - 25 mbar SR R UR2 int. UR2 ext.
Rated heating capacity (kW)
1.80 3.0 0.90 3.30
Nozzle diameter (1/100 mm)
94 121 68 128
Pre-chamber (printed on nozzle)
YF2F1F2
Reduced flow rate (W)
500 800 400 1200
4 Natural gas G25.1 - 25 mbar SR R UR2 int. UR2 ext.
Rated heating capacity (kW)
1.80 3.0 0.90 3.30
Nozzle diameter (1/100 mm)
100 134 72 136
Pre-chamber (printed on nozzle)
YF3H1F3
Reduced flow rate (W)
500 800 400 1200
5 Natural gas G25 - 20 mbar SR R UR2 int. UR2 ext.
Rated heating capacity (kW)
1.80 3.0 0.90 3.30
Nozzle diameter (1/100 mm)
100 134 72 138
Pre-chamber (printed on nozzle)
YF3F1F3
Reduced flow rate (W)
500 800 400 1200
6 Natural gas G2.350 - 13 mbar SR R UR2 int. UR2 ext.
Rated heating capacity (kW)
1.80 2.90 0.90 3.30
Nozzle diameter (1/100 mm)
120 165 91 180
Pre-chamber (printed on nozzle)
YF3YH4
Reduced flow rate (W)
500 800 400 1200