C. Using the required wire gage as per table 3 that meets all applicable electrical codes for the size of the
required breakers, run a ground wire and two pair of wires per breaker from the main breaker panel to the
tankless water heater unit. Refer to the corresponding wire connections to breakers chart above.
E. Double check the electrical connections to make sure they are correct and all the wire connections are tight
and secure, and the unit has been connected to a ground in accordance with applicable codes.
D. The ground wire must be connected to "ground" at the circuit breaker panel.
Model MS150C2TMU MS180C2TMU MS210C2TMU MS240C2TMU MS270C2TMU
Phase
1 1 1 1 1
Voltage V
240 V
240V
240 V 240 V 240 V
Wattage kW
15kw
18kw
21kw
24kw
27kw
Max.
amp.
load A
63
75
88
100
113
Min. required circuit breaker
A
2 X 40
2 X 50
3X 40
3X 40
3X 50
Min. wire size AWG cooper
2 X 8
2 X 8
3 X 8
3 X 8
3 X 8
Min. water flow to activate
GPM / L/min.
0.84/ 3.2
0.84/ 3.2
0.84/ 3.2
0.84/ 3.2
0.84/ 3.2
Working pressure PSI/bar
Max.150/10
Weight lb
17.6
Product Dimensions in
16.1 x 11 x 3.5
Water connections NPT
3/4”
3/4”
3/4”
3/4”
3/4”
17.6 17.6 17.6 17.6
16.1 x 11 x 3.5 16.1 x 11 x 3.5 16.1 x 11 x 3.5 16.1 x 11 x 3.5
Check your local electrical code requirements for different voltage application
Model
MS120C2T_U
MS150C2T_U
MS180C2T_U
MS210C2T_U
MS240C2T_U
MS270C2T_U
Phase
1
1
1
1
1
1
Voltage V
240
240
240
240
240
240
Wattage kW
12
15
18
21
24
27
Max. Amp. Load @ 240V
A
50
63
75
88
100
113
No. of circuits n
1
2
2
3
3
3
Min. required double pole
circuit breaker
A
60
2 x
40
2
x
50
3 x
40
3 x
40
3 x 50
Min. wire size AWG cooper
8
2 x 8
2 x 8
3 x 8
3 x 8
3 x 8
Min. water flow to activate
GPM / L/min.
0.84 / 3.2
0.84 / 3.2
0.84 / 3.2
0.84 / 3.2
0.84 / 3.2
0.84 / 3.2
Working pressure PSI/bar
Max.150/10
Weight
kg
lb
3.6
7.9
5.3
11.7
5.3
11.7
5.5
12.1
5.5
12.1
5.5
12.1
Product Dimensions mm
in.
385x260x93
15.1x10.2x3.7
385x260x93
15.1x10.2x3.7
385x260x93
15.1x10.2x3.7
385x260x93
15.1x10.2x3.7
385x260x93
15.1x10.2x3.7
385x260x93
15.1x10.2x3.7
Water connections NPT
1/2” 3/4” 3/4” 3/4” 3/4” 3/4”
No. of circuits
2 2 3 3 3
15
@ 240V
Table 4
Table 5
Injected Mold Model
Stainless Steel Model
Loading ...
Loading ...
Loading ...