35
to the right to increase the level of power;
to the left to decrease the level of power.
The power level set will be displayed in the Selection/Display
area (12)
Power Booster
The product has 2 additional power levels (above level 3)
Power Booster 1 : timed for 15 min.
Power Booster 2 : timed for 5 min.
after which the power returns to the previously set level.
Touch and slide with the fingers along the Selection bar (3) (over
level 3) and activate the Power Booster 1
The Power Booster level 1 is indicated in the Selection / Display
area (12) with the number "4" flashing
Touch and slide with the fingers along the Selection bar (3) (over
level 3) and activate the Power Booster 2
The Power Booster level 2 is indicated in the Selection / Display
area (12) with the symbol
” flashing
Automatic aspiration speed
The hood will turn on at the most suitable speed, adapting the
extraction capacity to the maximum cooking level used in the
cooking zone.
When the cooking zones are switched off, the hood adapts its
extraction speed, decreasing it gradually, to eliminate residual
vapours and odours.
To activate this function:
Press
(14)
Repeat the operation to deactivate.
Note: if during automatic operation are selected from the
Selection bar (3) the speeds from 1 to 3, the automatic operation
is interrupted;
if, instead, the Power Boosters are selected, automatic operation
will resume at the end of the timing, while in the meantime the
symbol
” remains flashing.
Note: if the hob automatically shuts down with Automatic mode
active, the extractor fan will automatically turn off in a gradual
manner.
Filter saturation indicator
The hood indicates when filter maintenance is needed:
Carbon/ceramic odour filters
”(13) comes on
Grease filter
”(13) flashes Note: this function is disabled by
default (see how to enable it in the paragraph "Activation filter
saturation indicator")
Reset filter saturation
After performing maintenance on the filters (greases and/or
carbon/ceramic), press and hold “
(13) ;
(13) turns off, restarting the indicator count.
Activation filter saturation indicator
This indicator is normally deactivated.
To activate it, proceed as follows:
• turn on the extractor hob via
;
• with the extraction motor and cooking zones off, press the
Selection zone (12)
• long press
” (11) until the letters “F” – “G” appear
alternately flashing in the Display (12)
F = carbon/ceramic odour filters
G = grease filter
Carbon/ceramic odour filters
.press on the Display (12) when the letter “F” appears
• press “
(13) – flashing light
• long press
(11) again to confirm the activation of
the carbon/ceramic odour filter indicator
Grease filter
• press on the Display (12) when the letter “G” appears
• press “
(13) – fixed light
•long press
(11) again to confirm activation of the
grease filter indicator
The device can also be used in combination with a Window
sensor KIT (not supplied by the manufacturer).
If the Window sensor KIT is installed (only in the case of use in
EXTRACTOR mode), air extraction will halt every time the window
in the room, on which the KIT is applied, is closed.
The KIT must be electrically connected to the device by
qualified and specialised technical personnel.
The KIT must be certified separately in accordance with the
safety standards for the component and its use with the
device. Installation must be carried out in accordance with
current regulations for domestic systems.
PLEASE NOTE:
the wiring of the KIT to be connected to the device must be
part of a certified safety extra-low voltage (SELV) circuit.
the manufacturer of this device declines all liability for any
inconvenience, damage or fires caused by defects and/or
problems associated with the malfunction and/or incorrect
installation of the KIT.