Firebox
Repack
insulation
knockout
Combustible
materials
Maintain air clearance
to combustibles.
Gas line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
Gas line
1 1/2 in. (38 mm)
air space around
pipe
Refractory
Seal with
fireplace mortar
or non-combust-
ible sealant
4 in.
(102 mm)
Outer shell
of fireplace
Figure 12.1 Gas Line Installation
12
Accessories
A. Gas Log/Lighter Provision
WARNING! Fire and/or Asphyxiation Risk!
Use with
solid wood fuel or decorative gas appliance only. Gas re
generates fumes.
DO NOT install unvented gas logs
Acertiedgasloglighterordecorativegaslogsetcanbe
installedinthisreplace.
• Maximuminputis100,000BTU/hr.
• Decorative gas appliance must be certied to ANSI
Z21.60 “Standard for Decorative GasAppliances for
InstallationinVentedFireplaces”.
• MustbeinstalledinaccordancewiththeNational Fuel
Gas Code, ANSI Z223.1.
• Agaslogsetmustincorporateagasshutoff.
• Knockoutsareprovidedonbothsidesofthereplace
andinrefractoriesfor1/2in.(13mm)ironpipe.
• Sealrefractoryaroundpipe with replacemortarora
non-combustiblesealant.
OutdoorLifestylesbyHearth&HomeTechnologiesInc.•4072-137RevK•10/15