Loading ...
Loading ...
Loading ...
34
3 in. (76 mm) tall legs
Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap
Length x Width to fit inside shroud
Figure 10.1 Radiation Shield
10
Shrouds
• Chase top shrouds may be eld constructed where
permittedbyregionalbuildingcodes.
WARNING! Risk of Fire! Shrouds must be constructed
as specied. Improper construction may overheat chase
top.
NOTICE: Some regional codes require an agency-Listed
shroud. Consult your local building ofcials.
• Hearth & Home Technologies Inc. supplies UL listed
shrouds.Seeyourdealerfordetails.
• The following eld constructed shroud designs have
beentestedforHearthTechnologiesreplacesystems
andterminationcaps.
• Theshroudsmustbeconstructedfromaminimum.018
in.(26ga)thickaluminizedsteel.
A. Radiation Shield
• Some shrouds require a radiation shield. Use where
specied.
• Radiationshieldmustbeconstructedofminimum26ga
sheetmetal.
3 in (76 mm)
minimum
Min.
Base Dim.
Min.
Base Dim.
Min.
Top Dim.
Min.
Top Dim.
Min. Opening
Width
Min. Opening
Width
Figure 10.2 Open Top Shroud Dimensions
B. Field Constructed Shrouds
• Thewiremeshisoptionalbutrecommendedandmust
be.018in.thickminimum,1/2in.mesh.
OutdoorLifestylesbyHearth&HomeTechnologiesInc.•4072-137RevK•10/15
TS345 TR342 TR342/344TV
Min. Base Dims.
in 23x23 28x28 26x26
mm 584x584 711x711 660x660
RadiationShield
Required
Min. Top Dims.
in 20x20 25x25 23x23
mm 508x508 635x635 584x584
Min. Opening Width
in 17x17 22x22 20x20
mm 432x432 559x559 508x508
Open Top Shroud (TR342 caps require radiation shield)
Loading ...