3 in. (76 mm) tall legs
Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap
Length x Width to fit inside shroud
Figure 10.1 Radiation Shield
10
Shrouds
• Chase top shrouds may be eld constructed where
permittedbyregionalbuildingcodes.
WARNING! Risk of Fire! Shrouds must be constructed
as specied. Improper construction may overheat chase
top.
NOTICE: Some regional codes require an agency-Listed
shroud. Consult your local building ofcials.
• Hearth & Home Technologies Inc. supplies UL listed
shrouds.Seeyourdealerfordetails.
• The following eld constructed shroud designs have
beentestedforHearthTechnologiesreplacesystems
andterminationcaps.
• Theshroudsmustbeconstructedfromaminimum.018
in.(26ga)thickaluminizedsteel.
A. Radiation Shield
• Some shrouds require a radiation shield. Use where
specied.
• Radiationshieldmustbeconstructedofminimum26ga
sheetmetal.
3 in (76 mm)
minimum
Min.
Base Dim.
Min.
Base Dim.
Min.
Top Dim.
Min.
Top Dim.
Min. Opening
Width
Min. Opening
Width
Figure 10.2 Open Top Shroud Dimensions
B. Field Constructed Shrouds
• Thewiremeshisoptionalbutrecommendedandmust
be.018in.thickminimum,1/2in.mesh.
OutdoorLifestylesbyHearth&HomeTechnologiesInc.•4072-137RevK•10/15
TS345 TR342 TR342/344TV
Min. Base Dims.
in 23x23 28x28 26x26
mm 584x584 711x711 660x660
RadiationShield
Required
Min. Top Dims.
in 20x20 25x25 23x23
mm 508x508 635x635 584x584
Min. Opening Width
in 17x17 22x22 20x20
mm 432x432 559x559 508x508
Open Top Shroud (TR342 caps require radiation shield)