20 ft (6.10 m) max.
pipe between an
offset & return
Ceiling Firestop
35 ft (10.67 m)
max. straight
unsupported
chimney height
14.5 ft (4.42 m) min. height/single offset-return
20 ft. (6.1 m) min. height/double offset-return
90 ft (27.43 m) max. height
6 ft (1.83 m) max.
unsupported chimney
above roof
39 1/2 in. (1003 mm)
Effective Height
Figure 8.2 Chimney Requirements
Determinethechimneycomponentsneededtocomplete
yourparticularinstallation:
Measure the total vertical height of the fireplace
installationfromthebaseofthereplaceassemblyto
theapproximatelocationofthebottomofthetermination
cap.
• Subtracttheeffectiveheightofthereplaceassembly
(seeFigure8.2)fromthetotalverticalheighttodetermine
theoverallheightofthechimneyinstallation.
• CreateaschematicforyourapplicationsimilartoFigure
8.2 showing components required (referring to Table
8.1).Figure8.1identiesthosecomponentsandwhere
used.
• Installaceilingrestopwheneverthechimneypenetrates
aoor/ceiling.
NOTICE: A maximum of two pairs of offsets and returns
may be used.
CAUTION! Risk of Fire and/or Asphyxiation! DO
NOT connect this replace to a chimney ue servicing
another appliance. DO NOT connect to any air distribu-
tion duct or system. These actions could cause over-
heating/re in the chimney ue, or release of exhaust
fumes into the living areas.
ft m
Minimumheightwithoffset/return 14.5 4.42
Maximumheight 90 27.43
Maximumchimneylengthbetweenanoffset
and return
20 6.1
Maximumdistancebetweenchimney
stabilizers
35 10.67
Doubleoffset/returnminimumheight 24 7.32
Maximumunsupportedchimneylength
betweentheoffsetandreturn
6 1.83
Maximumunsupportedchimneyheightabove
thereplace
35 10.67
Minimumoverallstraightheightifreplaceis
freestanding
6.4 1.95
MinimumStraightHeight 14.5 4.42
A. Chimney Requirements
Whenplanningyourreplacelocation,thechimneycon-
structionandnecessaryclearancesmustbeconsidered.
Thereplacesystemandchimneycomponentshave
beentestedtoprovideexibilityinconstruction.Thefol-
lowingguresaretheminimumdistancesfromthebase
ofthereplace.
Minimum overall straight height is 6 ft 4 in. if the
replaceisfreestandingandaminimumof10ftfroma
combustiblestructure. SeeFigure3.2.
• Chimneymustextend2ft(.6m)aboveanyportionofthe
roofwithin10ft(3m)ofthechimney.RefertoFigure6.1.
Table 8.1
HEIGHT OF CHIMNEY COMPONENTS in. mm
Chimney Stabilizer
SL3 4-3/4 121
Ceiling Firestops
FS338 0 0
FS339 0 0
FS340 0 0
Offsets/Returns
SL315 13-3/8 340
SL330 15-1/2 394
Roof Flashing
RF370 0 0
RF371 0 0
Chimney Sections*
SL306 4-3/4 121
SL312 10-3/4 273
SL318 16-3/4 425
SL324 22-3/4 578
SL336 34-3/4 883
SL348 46-3/4 1187
* Dimensions reect effective height.