Loading ...
user manual. Keep children away from the installation
site. After unpacking the appliance, make sure that it
has not been damaged during transport. In the event
of problems, contact the dealer or your nearest After-
sales Service. Once installed, packaging waste (plastic,
styrofoam parts etc.) must be stored out of reach of
children - risk of
The appliance must be
disconnected from the power supply before any
installation operation - risk of electrical shock. During
installation, make sure the appliance does not damage
the power cable - risk of or electrical shock. Only
activate the appliance when the installation has been
completed.
The electrical and gas connections must comply
with local regulation.
WARNING: of the appliance and its
method of installation are essential in order to use the
appliance safely and correctly in all the additional
countries.
Use pressure regulators suitable for the gas
pressure indicated in the instruction.
The room must be equipped with an air extraction
system that expels any combustion fumes.
The room must also allow proper air circulation, as
air is needed for combustion to occur normally. The
of air must not be less than 2 m
3
/h per kW of
installed power.
The air circulation system may take air directly from
the outside by means of a pipe with an inner cross
section of at least 100 cm
2
; the opening must not be
vulnerable to any type of blockages.
The system can also provide the air needed for
combustion indirectly, i.e. from adjacent rooms
with air circulation tubes as described above. However,
these rooms must not be communal rooms, bedrooms
Liquid petroleum gas sinks to the as it is
heavier than air. Therefore, rooms containing LPG
cylinders must also be equipped with vents to allow
gas to escape in the event of a leak. As a result LPG
cylinders, whether partially or completely full, must
not be installed or stored in rooms or storage areas
that are below ground level (cellars, etc.). It is advisable
to keep only the cylinder being used in the room,
positioned so that it is not subject to heat produced
by external sources (ovens,
stoves, etc.)
which could raise the temperature of the cylinder
above 50°C.
Carry out all cabinet cutting works before
the appliance in the furniture and remove all wood
chips and sawdust.
If the appliance is not installed above an oven, a
separator panel (not included) must be installed in the
compartment under the appliance.
Should you experience in turning the burner’s knobs, please contact
After Sales Service for replacement of the burner tap if found to be faulty.
The openings used for the ventilation and dispersion of heat must never be
covered.
GAS CONNECTION
WARNING: Prior to installation, ensure that the
local distribution conditions (nature of gas and gas
pressure) and the adjustment of the appliance are
compatible.
Check that the pressure of the gas supply is
consistent with the values indicated in Injectors Table.
WARNING: The adjustment conditions for this
appliance are stated on the label (or data plate).
WARNING: This appliance is not connected to a
combustion products evacuation device. It shall be
installed and connected in accordance with current
installation regulations. Particular attention shall be
given to the relevant requirements regarding
ventilation.
If the appliance is connected to liquid gas, the
regulation screw must be fastened as tightly as
possible.
IMPORTANT: When gas cylinder is adopted, the
gas
lid or cover.
cylinder or gas container must be properly settled
(vertical orientation).
WARNING: This operation must be performed by a
The cooktop is not suitable for use with aftermarket
Use only or rigid metal hose for gas
connection.
Connection with a rigid pipe (copper or steel):
Connection to the gas system must be carried out in
such a way as not to place any strain of any kind on
the appliance. There is an adjustable L-shaped pipe
on the appliance supply ramp and this is
with a seal in order to prevent leaks. The seal must
always be replaced after rotating the pipe
(the
seal is provided with the appliance). The gas supply
pipe is a threaded 1/2 gas cylindrical male
attachment.
Connecting a jointless stainless steel pipe
is a threaded 1/2 gas cylindrical male attachment.
These pipes must be installed so that they are never
longer than 2000 mm when fully extended. Once
connection has been carried out, make sure that the
metal pipe does not touch any moving parts
and is not compressed. Only use pipes and seals that
comply with current National regulations.
IMPORTANT: If a stainless steel hose is used, it must
be installed so as not touch any moving part of the
furniture (e.g. drawer). It must pass through an area
where there are no obstructions and where it is
possible to inspect it on all its length.
The appliance should be connected to the main
gas supply or to gas cylinder in compliance with the
current National regulations. Before carry out the
connection, make sure that the appliance is
compatible with the gas supply you wish to use. If this
is not the case, follow the instructions indicated in the
Loading ...