Troubleshooting
Before You call For Service
' If the unit appears to be malfunctioning, read through Normal Operation first, if the problem persists,
check the Troubleshooting Guide. Locate the problem in the guide and refer to the cause and its remedy
before calling for service. The problem could be something very simple which can be solved without a
service call.
TroubEeshooting Guide
Problem !ossible Cause !emedy
Unit does not operate. No electrical power to the unit. Make sure power cord is plugged in. Check for
blown fuse or tripped circuit breaker.
Cycle selector switch set Make sure cycle selector switch is set to ICE/ON
improperly. Surrounding air temperature must be at teast
..... Low air temperature around unit. 45°F (7°C).
Unit runs but no ice is produced. No water being supplied to the Check to see that water is connected and turned
unit. on to the unit.
Unit runs but produces very little ice.
Dirtycondensercoils.
Highair temperaturearoundunit.
Scale and mineral buildup in unit.
inadequate airflow at the front of
the unit.
Cleaning cycle recently performed
Cleanthe condenser.SeeMaintenance.
Surroundingair temperatureof over 90°F (32°C).
Lowice productionat high temperaturesis
normat.
Clean unit.See Maintenance.
Removeitemsblockingairflow.
Allowunitto reachthe settemperatureto produce
icenormally
Ice is slow to releaseor doesnot
releasefromthe evaporator.
Ice-makingsystemis dirty.
Unitis not level.
Low air temperaturearoundthe unit.
Run unit through automatic clean cycle. See
Maintenance.
See Leveling the Unit.
Surrounding air temperature must be at least 50°F
(10°C).