WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity before servicing. Check appliance is safe when you have nished.
41
5.5 To Change the Main Oven Burner Injector
Remove the main oven burner (see 5.3). The injector is now
accessible. Remove the old jet and t the new one.
Reassemble in the reverse order. Check that the ame
safeguard device probe has not been disturbed.
5.6 To Change the Oven Programming Flame Safeguard
Unit
n
Disconnect from the electricity supply.
Pull the cooker forwards to gain access to the cover box at the
rear of the cooker. See ‘Moving Your Cooker’ in the Installation
section.
Remove the screws securing the cover and lift clear. Noting
their positions, pull o all the leads to the PFS control unit.
Slacken the 3 screws holding the control unit to the cooker
and remove.
Fit the new PFS unit to the cooker and replace the leads. Refer
to the wiring diagram and reassemble in the reverse order.
Check the performance.
5.7 To Change the Main Oven Solenoid
n
Disconnect from the electricity supply.
Move the cooker forward to gain access to the rear. See
‘Moving Your Cooker’ in the installation section.
Remove the screws securing the cover and lift clear.
Disconnect the solenoid leads and remove the earth lead from
the earth screw. Unclip the wires from the cable ties.
Disconnect the pipe tube nuts to the solenoid unit. Unscrew
the locking nut from the end connector and the remove
solenoid unit. Fit the new unit to mounting bracket and x in
place with locking nut. Ret the tube nut connections.
Replace the leads (refer to the wiring diagram). Replace the
wires in cable ties. Check the appliance is gas sound. Ret the
cover box. Check for the correct operation of the solenoids.
5.8 To Change the Main Oven Electrode
n
Disconnect from the electricity supply.
Remove the main oven burner (see 5.3). Remove the screw
and nut securing the electrode to the burner. Pull the lead
from back of electrode and t to the new electrode. Fit the
new electrode to the burner.
Reassemble in the reverse order. Check the ignition.
5.9 To Change the Tall Oven Fan
n
Disconnect from electricity supply.
Pull the cooker forward to gain access to the rear. Remove
the screws securing the electric cover to the back sheet and
remove the cover.
Disconnect the 3 teminals connected to the fan, noting their
positions. Remove the tall oven inner back (see 5.1).
Hold the fan blade and remove the centre nut (left-hand
thread) brass washers (2 o), fan blade and circlip. Unscrew
the fan retaining nuts and washers (3 o each) and lift the
fan away from the rear of the cooker. Fit the new fan and
reassemble in reverse order.
Check the operation of the oven.