Fireplace Installation
power supply.
Connect the N and H1 wires
from the unit to the neutral
wire from the power supply.
Connect the L2 and H2 wires
together, with a wire connec-
tor and leave them discon-
nected from everything.
Attach the grounding wire to
the cover with the provided
grounding screw. Place wire
in-between screw and lock
washer and tighten (Figure 4).
Reposition the electrical cover
brackets over the wires and
connectors and attach to re-
place chassis using the screw
removed in step 1 and step 3.
For 240V Installations
Use three conductor, non-metallic
sheath cable with ground wire
(4 wires total) for the incoming
power supply on replace inserts.
CAUTION: Use the appropri-
ate wire to meet local and
national electrical codes for
rated power consumption.
Connect the L1 wire from the
unit to the L1 wire from the
power supply.
Connect the L2 wire from the
unit to the L2 wire from the
power supply.
Connect the N wire from the
unit to the neutral wire from
the power supply.
Connect the H1 and H2 wires
together, with a wire connec-
tor and leave them discon-
nected from everything.
Attach the grounding wire to
the cover with the provided
grounding screw. Place wire
in-between screw and lock
washer and tighten (Figure 4).
Reposition the electrical cover
brackets over the wires and
connectors and attach to re-
place chassis using the screw
removed in step 1 and step 3.
For Bathroom Use
If this unit is installed in a bath-
room it must be protected by a
GFI receptacle or circuit. If recep-
tacle is used it must be readily
accessible.
To prevent electrical shock this
Figure 4
Hole for
Ground Screw