25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A 5
Electrical
§ 115 V, 60 Hz, 1 phase, 11.0A
§ Connect to a 15A dedicated circuit.
§ Furnished with 7 ft (2 m) power cord with a 90° NEMA hospital grade 5-15 plug.
Ambient
Air temp* 100 F/38 C Max. 50 F/10 C Min. (Best performance below 80 F (27 C)
Water temp
90 F/32 C Max. 45 F/7 C Min. (Best performance below 70 F (21 C)
Water pressure (psi/bar) 70/5 Max. 10/0.7 Min.
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
Ambient water temperature is measured in the ice machine oat reservoir.
Plumbing
Connections 25/50CI425A Rough-ins 25/50HI425A
Dispenser drain 3/4" MPT Air-cooled 3/4" FPT
Water inlet 3/8" FPT 3/8" FPT
Condenser inlet Water-cooled 3/8" FPT N/A
Condenser outlet Water-cooled 3/8" FPT N/A
Note: Water shut-off recommended within 10 ft. (3m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
Air-cooled Water-cooled
Required for ventilation 3" (77 mm) each side N/A
Suggested for service 12" (30.5 cm) top,
6" (15.3 cm ) left side
12" (30.5 cm) top
Note: Do not block right side air intake or right side air exhaust.
Dry weight
§ 25/50CI425A/W (countertop): 215 lbs. (98 kg)
§ 25/50HI425A/W (wall mount): 230 lbs. (105 kg)