GE PZS23KSEDFSS Profile Series 23.3 Cu. Ft. Counter-Depth Side-by-Side Refrigerator

OWNER’S MANUAL & INSTALLATION INSTRUCTION - Page 35

For PZS23KSEDFSS. Series: Profile Series
Also, The document are for others GE - General Electric models: PZS22KSEDFSS, PZS25KSEDFSS, PZS26KSEDFSS, PZS27KSEDFSS, PZS29KSEDFSS

PDF File Manual, 144 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Installation Instructions
WHAT YOU WILL NEED (CONT.)
NOTE: The only GE approved plastic tubing is that
supplied in GE SmartConnect'" Refrigerator Tubing
kits. Do not use any other plastic water supply line
because the line is under pressure at all times.
Certain types of plastic will crack or rupture with
age and cause water damage to your home.
, AGE water supply kit (containing tubing, shutoff
valve and fittings listed below)is available
at extra cost from your dealer or from Ports
and Accessories, 800.626.2002 (in Canada
1.888.261.3055).
, A cold water supply. The water pressure must be
between 20 and 120 p.s.i. (1.4-8.1 bar).
, Power drill.
, I/2" or adjustable wrench.
, Straight and Phillips blade _..¢_._
screwdriver.
, Two 1/4" outer diameter compression nuts and 2
ferrules (sleeves}--to connect the copper tubing to
the shutoff valve and the refrigerator water valve.
OR
, If you ore using m GE SmartConnect _"
Refrigerator Tubing kit, the
necessary fittings ore preossembled
to the tubing.
, If your existing copper water line has o flared
fitting at the end, you will need on adapter
(available at plumbing supply stores) to connect
the water line to the refrigerator OR you con cut
off the flared fitting with m tube cutter and then
use o compression fitting. Do not cut formed end
from GE SmartConnecf" Refrigerator tubing.
, Shutoff valve to connect to the cold water line.
The shutoff valve should have mwater inlet with o
minimum inside diameter of 5/32< at the point of
connection to the COLD WATER LINE. Saddle-type
shutoff volves ore included in many water supply
kits. Before purchasing, make sure o saddle-type
valve complies with your local plumbing codes.
Install the shutoff volve on the nearest frequently
used drinking water line.
[i] SHUT OFF THE MAIN WATER SUPPLY
Turn on the nearest faucet long enough to clear
the line of water.
[Z] CHOOSE THE VALVE LOCATION
Choose o location for the valve that is easily
accessible. It is best to connect into the side of
o vertical woter pipe. When it is necessary to
connect into m horizontal water pipe, make the
connection to the top or side, rather than at the
bottom, to ovoid drawing off any sediment from
the water pipe.
I_I DRILL THE HOLE FOR THE VALVE
Drill o 1/4" hole in the water pipe (even if using
o self-piercing valve), using a sharp bit. Remove
any burrs resulting from drilling the hole in the
pipe.
Take care not to allow water to drain into the
drill.
Failure to drill o 1/4" hole may result in reduced
ice production or smaller cubes.
35
Loading ...
Loading ...
Loading ...