USING YOUR REFRIGERATOR
Performance Data Sheet
Models Number ADQ72910907
Use with replacement cartridge ADQ72910907
ThissystemhasbeentestedaccordingtoNSF/ANSIStandards42forthereductionofthesubstanceslisted
below. The concentration of the indicated substances in water entering the system was reduced to a concentration
lessthanorequaltothepermissiblelimitforwaterleavingthesystemasspeciedinNSF/ANSI42.
SystemtestedandcertiedbyNSFInternationalagainstNSF/ANSIStandard42forthereductionof
Chlorine Taste and Odor and Nominal Particulate Class III.
Capacity:500gal(1,892L)
Substance
Average
Inuent
Concentration
InuentChallenge
Concentration.
Units apply to
each row
Avg. Product
Water
Concentration
Average
%
Reduction
NSF % reduction req.
or Max. permissible
product water
concentration
Nominal Particulate
Class I Particle size: ›0.5 to ‹1 um
24,333
At least 10,000
particles/ml
915 96
≥85%
Chlorine taste and
odor
Class III
1.9 2.0mg/L±10% 0.07 96.4 ≥50%
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
ApplicationGuidelines/WaterSupply
Parameters
Serviceow 0.5gpm(1.89lpm)
Water pressure 20-125psi(138-862
kPa)
Water temperature
33ºF-100ºF(0.6ºC-
38ºC)
WARNING
To reduce the risk associated with ingestion
of contaminants due to use with water that is
microbiologically unsafe or of unknown
quality. Do not use with water that is
microbiologically unsafe or of unknown
quality without adequate disinfection before
or after the system.
Systems must be installed and operated in accordance
with manufacturer’s recommended procedures and
guidelines.
CAUTION
To reduce the risk of property damage due to water
leakage:
• Read and follow the Use & Care guide instructions
before installation and use of this system.
• Install on COLD water lines only.
• Comply with all state and local plumbing codes.
• Install a pressure limiting device and water
hammer arrester for inlet water pressures
exceeding80psi(552kPa).RefertoUniform
• Plumbing Code, Sections 608.2 and 609.10.
• Never install or operate where inlet water pressure
mayexceed120psi(827kPa).
• Protectlterfromfreezing.Removelterin
temperaturesbelow33°F(0.6°C).
• Replacecartridgeatspeciedserviceinterval.
Cartridge MUST be replaced at least every 6
months.
Topurchaseareplacementwaterlter,call1-800-469-
4663 and ask for Part. No. ADQ72910907.
WATER FILTER