MODEL
PRESSURE
The allowed static pressure range of the
air condioner
on site is 0-200Pa.
Test static pressure
12-24K
25Pa 37Pa
50Pa
30-36K 48-60K
Safety
Precautions
Page 6
WARNINGS FOR PRODUCT INSTALLATION
1.
Installaon must be performed by an authorized dealer or specialist. Defecve installaon can
Excessive Weight Hazard - Use two or more people when moving and installing the unit. Failure
to do so can result in back or other type of injury.
cause water leakage, electrical shock, or fire.
2.
Installaon must be performed according to the installaon instrucons. Improper installaon
can cause water leakage, electrical shock, or fire.
(In North America,installaon must be performed in accordance with the requirement of NEC
and CEC by authorized personnel only.)
3.
Contact an authorized service technician for repair or maintenance of this unit. This appliance
shall be installed in accordance with naonal wiring regulaons.
4.
Only use the included accessories, parts, and specified parts for installaon. Using non-standard
parts can cause water leakage, electrical shock, fire, and can cause the unit to fail.
5.
6.
Install the unit in a firm locaon that can support the unit’s weight. If the chosen locaon cannot
support the unit’s weight, or the installaon is not done properly, the unit may drop and cause
serious injury and damage.
7.
8.
9.
10.
11.
12.
Do not turn on the power unl all work has been completed.
When moving or relocang the air condioner, consult experienced service technicians for
disconnecon and reinstallaon of the unit.
How to install the appliance to its support, please read the informaon for details in "indoor unit
installaon" and "outdoor unit installaon" secons .
For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of
any combusble materials.
Do not
install the unit in a locaon that may be exposed to combusble gas leaks. If combusble
gas accumulates around the unit, it may cause fire.
Install drainage piping according to the instrucons in this manual. Improper drainage may
cause water damage to your home and property.
Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)
1.
This air-condioning unit contains fluorinated greenhouse gasses. For specific informaon on the
type of gas and the amount, please refer to the relevant label on the unit itself or
the
“Owner's Manual - Product Fiche ” in the packaging of the outdoor unit.
(European Union
products only)
.
2.
Installaon, service, maintenance and repair of this unit must be performed by a cerfied
technician.
3.
Product uninstallaon and recycling must be performed by a cerfied technician.
4.
For equipment that contains fluorinated greenhouse gases in quanes of 5 tonnes of CO
2
equivalent or more, but of less than 50 tonnes of CO
2
equivalent, If the system has a leak-
detecon system installed, it must be checked for leaks at least every 24 months.