R L G B W E
C
Y1
DH
W1 W2
INDOOR UNIT
S4-2 DIP switch off
Perform disconnecon and
short-circuit to achieve
paron, control or
dehumidificaon
S4-1 DIP switch off
Disconnect and short
circuit to realize heang
segment
24V control DIP switch:
NOTE:
The wind gear DIP switch can only change the air volume when the electric heang is turned on, and the
air condioner cooling and heang air volume remains unchanged. If the DIP switch is wrong, the default
wind gear will be run.
000 gear (default)
air volume(CFM)
001 air volume(CFM) 010 air volume(CFM) 011 air volume(CFM)Model
24K
18K
30K
60K
48K
36K
660 570600630
10KW 5KW、3KW
8KW、5KW
8KW10KW 、8KW
15KW 10KW、8KW15KW 、10KW
8KW、5KW20KW 10KW、8KW15KW
8KW20KW 10KW、8KW15KW 、10KW
10KW25KW 15KW、10KW20KW 、15KW
15KW 5KW、3KW10KW、8KW15KW 、8KW
880
1100
1320
1760
2195
850
1040
1255
1675
2055
830
990
1190
1580
1920
800
930
1125
1490
1775
Air volume table
Wiring
Page 46