D
t
Recommended size of lter
Mount positions
Installation place
The units can be installed in a vercal (down
and up)and Horizontal(right and le)
configuraon.
Vertical up installations
Vertical installations
Horizontal installations
24inch(min)
24inch(min)
Page 18
Indoor Unit
Installation
W
MODEL(Btu/h)
12-24K
30-48K
W
16
495.3
60K 584.2
D
20
20
20
508
508
508
t
1
1
1
25.4
24.4
25.4
(unit: inch/mm)
406.4
19-1/2
23
inch mm inch mm inch mm
Model Afor North America models
MODEL(Btu/h)
60K
W
495.3
D
508
20
t
25.4
1
19-1/2
inch mm inch mm inch mm
Model B
IMPORTANT
A field-fabricated secondary drain pan, with a
drain pipe to the outside of the building, is
required in all installaons over a finished living
space or in any area that may be damaged by
overflow from the main drain pan. In some
localies, local codes may require a secondary
drain pan for any horizontal installaon.
DUCT CONNECTIONSAir supply and return
may be handled in one of several ways best suited
to the installaon (See table for dimensions for
duct inlet and outlet connecons). The vast majority
of problems encountered with combinaon cooling
systems can be linked toimproperly designed or
installed duct systems, it is therefore highly
important to the success of an installaon that the
duct system be properly designed and installed.
Use flexible duct collars to minimize the transmission
of vibraon/noise into the condioned space.
Where return air duct is short, or where sound is
liable to be a problem, sound absorbing glass fiber
should be used inside the duct. Insulaon of duct
work is a must where it runs through an uncooled
space during the cooling season. The use of a vapor
barrier is recommended to prevent absorpon of
moisture from the surrounding air into the insulaon.
The supply air duct should be properly sized by
use of a transion to match unit opening. All ducts
should be suspended using flexible hangers and
never fastened directly to the structure. This unit
is not designed for nonducted (freeblow)
applicaons. Duct work should be fabricated and
installed in accordance with local and/or naonal
switchs.