Electrical Wiring
WARNING
Attention
Follow local codes when selecting wire gauge and connecting to house power.
Use the cable strain relief clips and locking conduit clamps to prevent wires from being pulled off terminal posts.
Unit must be properly grounded. Do not use water or gas piping, phone ground or lightning rod.
Only copper wire can be used. A properly sized breaker should be provided, or electric shock may occur.
Unit requires 208/230VAC - 2 voltage wires and a ground. No neutral.
All indoor units should be wired to the same breaker to prevent some of the units from being powered off while others
are energized.
Controller wiring and refrigerant tubing can be arranged and ran together.
Disconnect power from both outdoor and indoor units prior to servicing any component in the system.
Supply Wiring Drawing
Indoor units and outdoor units should be connected to separate power breakers.
Indoor units must share one single electrical breaker. Circuit breaker specications should be calculated. It is
recommended to have both indoor & outdoor units connected to GFCI and surge devices.
power source: 208/230V~, 60Hz
outdoor
L1(L) L2(N)
power source: 208/230V~, 60Hz
Indoor 1
Indoor 2 Indoor 9
L1(L) L2(N)
L1(L) L2(N)
L1(L) L2(N)
......