Loading ...
Loading ...
Loading ...
EN
22
Installation
www.bora.com
XO
The settings made are saved and will not be affected when the
system is disconnected from the mains.
XO
The final mains connection to the appliances may only be set
up by certified specialists.
5.11 Function test
XX
Carry out a thorough function test on all appliances.
XX
In the event of error messages, see the “Troubleshooting”
chapter in the operating instructions.
5.12 Sealing the appliances
1
Fig. 5.25 Silicone sealant for ush installation
[1] Black, heat-resistant silicone sealant
1
Fig. 5.26 Silicone sealant for surface mounting
[1] Black, heat-resistant silicone sealant
XX
Once all of the installation work and initial operation is
complete, seal the appliances all the way round (also between
the cooktop extractor and cooktop) with black, heat-resistant
silicone sealant [1].
XX
Make sure that no silicone sealant gets under the cooktop.
5.13 Handover to user
Once installation is complete:
XX
Explain the main functions to the user.
XX
Explain all safety-related aspects of operation and handling to
the user.
XX
Affix the supplied nameplate to the back of these instructions.
XX
Provide the user with the accessories and all accompanying
documents, which are to be kept in a safe place.
i
A damaged power supply cable must be replaced by
another suitable power supply cable. This may only be
done by an authorised member of the After Sales Service
team.
Power supply cable requirements and connection diagram
Connection Fuse
protection
Minimum
cross-section
Power supply
cable
1-phase
connection
1 x 16A 1.5mm² Type H05VV-F or
H05VVH2-F
Tab. 5.4 Fuse protection and minimum cross-section
1
L1
2
N PE
220 - 240 V~
Fig. 5.24 1-phase connection diagram
Connecting the cooktop to the mains
XX
Switch off the main switch/automatic circuit breaker before
connecting the cooktop.
XX
Secure the main switch/automatic circuit breaker against
being switched back on without permission.
XX
Make sure the power to the appliance is disconnected.
XX
Only connect the cooktop using a permanent connection to a
power supply cable.
XX
Check that installation has been carried out correctly.
XX
Switch on the main switch/automatic circuit breaker.
XX
Put the cooktop into operation (see the Operation chapter).
XX
Check that all the functions are working correctly.
5.9 Basic configuration
When installation is complete, you must carry out the basic
settings (these settings can be changed at any time later on).
i
You can see precise instructions on the basic
configuration and all necessary information in the
Configuration menu chapter of the operating instructions.
XX
Follow the instructions on the basic configuration (see
Operating instructions – “Configuration menu” chapter).
5.10 Initial operation
i
You will find detailed information on operating the BORA
Professional 3.0 system in the operating instructions (see
“Functions and operation” chapter).
XX
Ensure that all appliances are connected correctly and
connected to the power supply (fused) prior to initial
operation.
XO
Exception: During initial operation, the kitchen fitter may use
a temporary power supply for the control unit in order to carry
out the basic configuration (e.g. using the site power supply
during the building phase).
Loading ...