Loading ...
Loading ...
Loading ...
WARNING: Before beginning work, shut off the power supply to avoid electrical shock.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Fan does not move.
1. Push switch firmly either left or
right.
2. Turn power on or check fuse.
3. Turn power off. Loosen canopy
and check all connections.
4. Check that male and female
plugs in light kit fitter are
connected properly according to
instructions on page 13.
Noisy operation. 1. Blades are loose.
2. Cracked blade.
3. Full range dimmer switch.
4. Fan is new.
1. Tighten all blade screws.
2. Replace blade.
3. Replace with an approved
speed control device.
4. Allow fan a “break in” period of
a few days, especially when
running the fan at Medium and
High speeds.
Excessive wobbling.
1. Blades are loose.
2. Unbalanced blades.
3. Fan not securely mounted.
4. Fan too close to vaulted ceiling.
5. Set screw(s) on motor housing yoke
is (are) not tightened properly.
6. Set screw on hanging ball is not
tightened properly.
1. Tighten all blade screws.
2. Switch one blade with a blade
from the opposite side.
3. Turn power off. Carefully loosen
canopy and verify that mounting
bracket is secure.
4. Use a longer downrod or move
fan to another location.
5. Tighten yoke set screw(s)
securely.
6. Carefully loosen and lower
canopy and verify that set screw
on hanging ball is tightened
securely.
NOTE: A small amount of "wobble" is normal and should not be considered a defect.
TROUBLESHOOTING
17
Fan operates but
light fails (if
applicable).
1. Wires in canopy not wired
properly.
2. Wall switch to fan is off.
3. Wires in light kit fitter not wired
correctly.
1. Check wires in canopy and, if
necessary, re-wire according to
instructions on pages 11 and 12.
2. Make sure that wall switch to
fan is on.
3. Check that molex connections
in light kit fitter are connected
properly according to
instructions on page 14.
1. Reverse switch not engaged.
2. Power is off or fuse is blown.
3. Faulty wire connection.
4. Wires in light kit fitter not wired
correctly.
Loading ...