Napoleon HDX52NT2 STARfire Series Direct Vent Natural Gas Fireplace

User Manual - Page 6

For HDX52NT2.

PDF File Manual, 132 pages, Read Online | Download pdf file

HDX52NT2 photo
Loading ...
Loading ...
Loading ...
6
W415-2180 / A / 11.28.16
EN
This appliance is approved for bathroom, bedroom, and bed-sitting room installations and is certifi ed for
mobile home installation.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
When the appliance is installed at elevations above 4,500ft (1371m), and in the absence of specifi c
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m).
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected. Change in fl ame appearance from “HI” to “LO” is more evident in natural gas than in propane.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance
and must be installed.
2.3 GENERAL INFORMATION
4.1C
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed
in accordance with the current standard CAN/CSA
Z240MH Series, for gas equipped mobile homes, in
Canada or ANSI Z223.1 and NFPA 54 in the United
States.
A
s long as the required clearance to combustibles is
maintained, the most desirable and benefi cial location for an appliance is in the center of a building, thereby
allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the
room where the appliance is to be located should be considered. If possible, you should choose a location
where the vent will pass through the house without cutting a fl oor or roof joist.
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certied in the U.S.
by the National Fireplace
Institute
®
(NFI) as NFI Gas
Specialists
www.ncertied.org
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
HDX52-2
NG P
Altitude (FT) 0-4,500 0-4500
Max. Input (BTU/HR) 55,000 55,000
Max. Output Steady State (BTU/HR) 37,391 36,500
Effi ciency (w/the fan on) 64% 68%
Min. Inlet Gas Supply Pressure 4.5" w.c. (11mb) 11" w.c. (27mb)
Max. Inlet Gas Supply Pressure 13" w.c. (17mb) 13" w.c. (32mb)
Manifold Pressure (Under Flow Conditions) 3.5" w.c. (9mb) 10" w.c. (25mb)
Loading ...
Loading ...
Loading ...