38
W415-2180 / A / 11.28.16
EN
(4) AA Batteries
8.0 OPERATION
Low battery alarm
Key Lock
Room
Temperature
LED Light
Flame ON
Blower
Transmission
CPI mode
8.1 GENERAL TRANSMITTER LAYOUT
8.2 INITIALIZING THE TRANSMITTER/BATTERY HOLDER FOR THE FIRST TIME
A. Install the 4 AA batteries into the Profl ame 2 battery holder, note the polarity of the batteries and
insert as indicated on the cover (+/-).
B. Ensure the 3 position slider switch is switched to the “REMOTE” position (middle position).
C. Press the reset/programming button, use a small object such as a paper clip in order to reach the
button marked PRG, as shown in the illustration below.
D. The battery holder will beep 3 times to indicate that it’s ready to synchronize with the transmitter.
E. Install the 3 AAA batteries into the transmitter, as shown in the photograph below, then press the ON
button, The battery holder will beep 4 times to indicate that the transmitter’s command is accepted.
NOTE: THE INITIALIZING PROCESS MUST BE COMPLETED WITHIN 10 SECONDS OF PRESSING THE
RESET/PROGRAM BUTTON (PRG).
Low Battery Alarm
TRANSMITTER
RESET/PROGRAM
BUTTON (PRG)
BATTERY HOLDER
SLIDER SWITCH
Loading ...