Napoleon EPI3TN Oakdale EPI3 Series Natural Vent Woodburning Fireplace

User Manual - Page 13

For EPI3TN.

PDF File Manual, 80 pages, Read Online | Download pdf file

EPI3TN photo
Loading ...
Loading ...
Loading ...
W415-1087 / A / 06.06.13
13
EN
4.2 INSTALLING THE EPI3
A. Flue collar orientation
Prior to installation, if possible, determine the type of orientation that works best with your appliance.
The orientation of the ue collar can be in a vertical position, or you may also choose to allow for a 30 degree
backwards angle by rotating the ue collar 180 degrees, at the top of the appliance.
When deciding on the cleaning method for your chimney we recommend cleaning from the top, chimney
cap, downwards. This way the centre bar of the ue collar protects the baf e inside the appliance from any
damages the chimney brush may cause. However, if cleaning must be done from inside the home, cutting the
centre bar inside the ue collar can be done using a reciprocating metal cutting saw or hack saw.
B. Installing a venting system
We recommend that the installation of the connector or ue liner be completed prior to continuing, however
this may differ depending on your application. See Figure 1 for venting system components.
1. Remove the front air tube to gain access to the ber baf e, and then also remove the ber baf e.
2. Remove the iron ue collar from the appliance. Ensure gasket is in place, and in good condition.
3. Drill three holes into the adapter pipe or ue liner using the holes in the iron collar as a guide. Secure
the adapter pipe, or ue liner to the ue collar. Take care to ensure the studs on the ue collar are
properly aligned to their respective holes on the insert.
4. Using the previously outlined method secure the exible pipe to the pipe adaptor.
5. The nished height measurements from the hearth surface to the center bar of the ue collar should
be 19” (482.6mm), see Figure 2 for details on the installation of the connector pipe or liner. This
allows for an easy connection, once the appliance is in place.
FLEXIBLE FLUE LINER
FLEX LINER ADAPTER
(IF REQUIRED)
ADJUSTABLE (30” (762mm) OR
VERTICAL) FLUE COLLAR WITH
INTEGRATED DRAW-DOWN BAR
TOP OF INSERT
AROUND FLUE OPENING
WASHERS (1/4” (6.4mm) DIAMETER)
1/4 - 20 HEX NUTS
30°
18
7
/
8
(479.4mm)
FIG. 1 FIG. 2