Installation
*INSTALLATION*
72
Flush-fit installation
Flush-fit installation is only possible in
natural stone (granite, marble), solid
wood and tiled worktops. Certain
models are suitable for building into
glass worktops – please see the relev-
ant label on the hob. When using a
worktop made from any other mater-
ial, please check first with the worktop
manufacturer that it is suitable for in-
stalling a flush-fit hob.
The internal width of the base unit un-
derneath the appliance must be at
least as wide as the inner worktop cut-
out (see “Installation – Building-in di-
mensions – flush fit”), so that the hob
is easily accessible from underneath
after installation and the bottom half of
the casing can be removed for main-
tenance. If the underside of the hob is
not freely accessible after installation,
any sealant used to plug the gaps
around the appliance must be re-
moved to enable the hob to be lifted
out of the cut-out should this be ne-
cessary.
Natural stone worktops
The hob is set directly in the cut-out.
Solid wood worktops, tiled worktops,
glass worktops
The hob is secured inside the cut-out
with wooden battens. The battens must
be provided on site, and are not sup-
plied with the appliance.
Minimum plinth height
The minimum plinth height is 100mm.
Housing unit back panel
The extraction ducting is laid behind the
housing unit back panel. The back
panel must be removable for mainten-
ance purposes.
Drip tray
The hob must be installed such that the
drip tray is easily accessible as it needs
to be removed for cleaning.
Sealing strip
Dismantling the hob for service pur-
poses may damage the sealing strip
underneath the edge of the hob.
Always replace the sealing strip be-
fore reinstalling the hob.