COMMISSIONING
All water heaters are tested and adjusted before dispatch from the factory, however further adjustments may
become necessary because of local conditions.
TO TURN ON THE WATER HEATER
Open all of the hot taps in the house (don’t forget the shower).
Open the cold water isolation valve fully at the inlet to the water heater.
Air will be forced out of the taps.
Close each tap as water flows freely from it.
Check the pipe work for leaks.
Open the gas isolation valve fully.
Check the gas pipe work for leaks.
Plug in the water heater at the power outlet and switch on the electrical supply.
Turn on a controller, if one is fitted, by pressing the on / off ( ) button.
The on / off operating light and the priority light will both glow.
Open a hot tap.
The water heater will operate automatically.
Check to ensure the flow from each connected hot tap is sufficient to operate the water heater.
The minimum operating flow rate for all models is 1.5 Litres per minute.
Check and if required adjust the preset outlet temperature setting of the water heater.
Refer to “Preset Outlet Temperature Setting” on page 77.
Check and if required adjust the outlet compensation temperature adjustment on an 876 series water
heater.
Refer to “Outlet Compensation Temperature Adjustment 876 Series” on page 79.
The automatic water governor incorporated in the water heater is not adjustable.
To complete the installation, it is necessary to check the gas supply pressure at the inlet to the water heater
(refer to “Gas Inlet Pressure” on page 73), the minimum test point pressure and the maximum test point
pressure (refer to “Burner Gas Pressure” on page 75).
Upon completion and testing of the installation, ensure the controller(s) is turned off (if fitted). Explain to the
householder or a responsible officer the functions and operation of the water heater and the controllers (if
fitted).
Warning: Upon completion of the installation and commissioning of the water heater, leave this guide with
the householder or a responsible officer. DO NOT leave this guide inside of the cover of the water heater, as
it may interfere with the safe operation of the water heater or ignite when the water heater is turned on.
GAS INLET PRESSURE
IMPORTANT - CHECK the gas supply pressure at the inlet to the water heater with the water heater and all
other gas burning appliances in the premises operating (burners alight). The minimum gas supply pressure is:
Natural Gas 1.13 kPa Propane, ULPG 2.75 kPa
If this minimum cannot be achieved, it may indicate the meter or the gas line to the water heater is undersized.
It is important to ensure that an adequate gas supply pressure is available to the water heater when other gas
burning appliances, on the same gas supply, are operating.