Rheem 876T26PF 26L Metro Max LPG Hot Water System

User Manual - Page 62

For 876T26PF.

PDF File Manual, 84 pages, Read Online | Download pdf file

876T26PF photo
Loading ...
Loading ...
Loading ...
EZ-LINK SYSTEM DUAL INSTALLATION
62
DUAL INSTALLATION
The two continuous flow water heaters can be installed side by side with minimal clearance between them.
The AGA has approved the installation of two of this model water heater with an exemption from the 300 mm
minimum clearance requirements between flue terminals, as stated in AS/NZS 5601, clause 5.13.6.5 and
AS/NZS 5601.1, clause 6.9.3.
Install two continuous flow water heaters of the same model in a parallel plumbing arrangement. It is good
practice, but not essential, to install the two water heaters in an Equa-Flow
®
manifold plumbing arrangement.
There are basic installation requirements which must be followed:
1. The pipe work must be sized to meet the requirements of both AS/NZS 3500.4 and the application. It is
recommended to use minimum DN25 pipe for the cold water line, cold and hot headers and hot water line
and DN20 for the cold and hot water branch lines of each water heater.
2. A full flow gate valve or ball valve must be installed on the cold water line to the system. A non-return
valve or stop tap must not be installed.
3. A full flow gate valve or ball valve (not a stop tap) should be installed on both the cold water branch and
hot water branch of each water heater.
4. An isolation valve must be installed on the gas branch of each water heater.
5. Non-return valves or pressure limiting valves must not be installed on the branch lines to the water heaters.
6. All fittings, valves and branch lines should be matched sets to each of the water heaters.
7. Sufficient space must be left to enable access, servicing or removal of either water heater.
A second rating label is attached to the inside of the front cover. This can be referenced to determine details
of the left hand water heater.
Refer to the Typical Two Unit Manifold with Ez-Link Connection diagram on page 65 for installation and plant
layout details.
TEMPERATURE CONTROLLER
A temperature controller may be installed with the EZ-Link system. The controller can be either a standard or
Deluxe controller. Rheem 874 and 876 series 824, 826 and T26 model water heaters do not require a
temperature controller to be installed as part of an Ez-link system installation.
Connect a temperature controller to one only of the two water heaters. Up to three temperature controllers of
the same family can be installed to this water heater. Refer to “Installation – Controllers” on page 66.
The water heater connected with the temperature controller(s) will become the master” water heater. The
installed temperature controller(s) will control the temperature and functionality of both water heaters. The
maximum outlet temperature of the water heaters will be limited by the maximum temperature setting of the
temperature controller.
A temperature controller should not be installed if two 874 series 824, 826 or T26 model water heaters have
been Ez-Linked together and they are part of a circulated hot water flow and return system in a building. Refer
to “Circulated Hot Water Flow And Return System” on page 51.