Napoleon GX36NTRE1 Ascent Series Direct Vent Natural Gas Fireplace

User Manual - Page 63

For GX36NTRE1.

PDF File Manual, 164 pages, Read Online | Download pdf file

GX36NTRE1 photo
Loading ...
Loading ...
Loading ...
63
W415-1678 / 08.09.16
EN
It’s important to periodically perform a visual check of the pilot and
burner ames. Compare them to the illustrations provided. If any ame
appears abnormal call a service person.
54.2A
3/8” - 1/2”
FLAME MUST
ENVELOP UPPER
3/8" TO 1/2"
(12.7mm - 9.5mm) OF
THERMOCOUPLE &
THERMOPILE
(9.5mm - 12.7mm)
MILLIVOLT
ILLUSTRATED
B36
GX36-1
10.3 FLAME CHARACTERISTICS
10.4 OPTIONAL ANTI CONDENSATION SWITCH
(MODELS B36NTRE/B36PTRE/GX36NTRE-1 & GX36PTRE-1 ONLY)
This appliance has the option to change from an electronic intermittent pilot ignition (IPI) to a standing pilot for
cold climates. The anti condensation control (standing pilot) is located in the center of the control panel. Using
your fi nger, fl ip the switch up for standing pilot, or down for intermittent pilot ignition.
Turning the ACS switch on will allow the pilot fl ame burning to burn continuously. This mode will minimize the
condensation which forms on the inside of the glass when the main burner is fi rst turned on. It will also help
the fi replace and vent system stabilize more quickly during the colder winter months.
During the warmer winter and summer months, the ACS switch can be turned off to minimize fuel
consumption.
Loading ...
Loading ...
Loading ...