45
W415-1678 / 08.09.16
EN
3" [76mm]
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
3" [76mm]
MINIMUM
3" [76mm]
2"
[51 mm]
1"
[25mm]
50 1/2"
[1283mm]
54"
[1372mm]
CEILING
(MIN)
42 5/8"
[1083mm]
MINIMUM
PLUS RISE*
1"
[25mm]
15 5/8”
[403 mm]
TOP EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 50 1/2" (1282mm). For temperature requirements,
the enclosure space around and above the appliance must be left unobstructed.
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible
wall penetration.
* See "MINIMUM FRAMING DIMENSION" section for details on reducing vent pipe top clearances.
These parameters also apply to the illustrations found in the "MINIMUM ENCLOSURE
CLEARANCES" section.