Kenmore 11088752790 washer/dryer laundry system

User Manual - Page 27

For 11088752790.

PDF File Manual, 68 pages, Download pdf file

Loading ...
Loading ...
Loading ...
IV. FOUR-WIRE ELECTRICAL
CONNECTION (DIRECT WIRE)
Prepare cable as directed:
Fire Hazard
Use 10 gauge solid copper wire.
Use UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or center
wire) to center terminal (silver).
Ground wire (green or bare wire)
must be connected to green ground
connector.
Connect remaining 2 supply wires
to remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to follow these instructions
can result in death, fire, or electrical
shock.
The laundry center can be connected
directly to fused disconnect or circuit
breaker box with four-wire flexible armored
or nonmetallic sheathed copper cable
(with grounding wire). All current-carrying
wires must be insulated. The grounding
wire may be bare.
A conduit connector must be installed
at junction box. Allow four feet of slack
in the line so laundry center can be
moved if servicing is ever necessary.
GROUNDING INSTRUCTIONS
This appliar=ce must be connected to
a grounded metal, permanent wiring
system; or an equipment-grounding
conductor must be run with the circuit
conductors and connected to the
equipment-grounding terminal or
lead on tt'e appliance.
STEP 1. Disconnect power.
STEP la. Strip 5 inches of outer
covering from end of cable. Leave
bare grounding wire at 5 inches,
J
STEP lb,, Cut 11/2inches from
3 remaininc insulated wires. Strip
insulation back 1 inch. Shape the end
of each wire into a "U" shaped hook.
STEP 2. Remove hold-down screw
and termin_LI block cover,
Terminalblockcover H01d-d0wnscrew
i
Loading ...
Loading ...
Loading ...