1311302 Daikin Dual-Zone Mini Split System with with 34400 BTU Cooling Capacity, 36000 BTU Heating Capacity and 2x Wall Mounted Indoor Units

User Manual - Page 216

For 1311302.

PDF File Manual, 299 pages, Read Online | Download pdf file

1311302 photo
Loading ...
Loading ...
Loading ...
Troubleshooting for Outdoor Unit SiUS121827E
210 Part 6 Service Diagnosis
7.9 DC Fan Lock
Error Code E7
Outdoor Unit LED
Display
A j 1 i 2 i 3 i 4 i 5 h
Method of Error
Detection
An error is determined with the high-voltage fan motor rotation speed detected by the Hall IC.
Error Decision
Conditions
The fan does not start in 30 seconds even when the fan motor is running.
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 5 minutes without any other error
Supposed
Causes
Disconnection of the fan motor
Foreign matter stuck in the fan
Defective fan motor
Defective outdoor unit PCB
Loading ...
Loading ...
Loading ...