W415-1343 / A / 11.18.16
9
EN
While the liners must be continuous from the appliance to the chimney cap,
to achieve the needed length, they may be coupled, using an approved
coupler.
We recommend that exhaust vents that pass through unheated spaces,
such as tall exterior chimneys, be wrapped in a protective sleeve to minimize
condensation and reverse flow symptoms. See "TROUBLESHOOTING"
section for details.
This appliance is approved for use with a 3" (76mm) exhaust and air intake.
A. OUTSIDE: Slip the one end of a liner a minimum of 2"( 51mm)
over the sleeve of the air terminal. Secure using 3 screws. Then seal the joint and screw heads with
high temperature sealant. Repeat with the other liner.
NOTE: We recommend that the other end of the exhaust liner be marked to eliminate the
exhaust liner being connected
to the intake collar at the
appliance.
B. Gently stretch the liners to the
required lengths and insert
into the chimney. Trim and fit
the flashing plate to suit the
chimney termination. Place the
air terminal onto the top of the
chimney. Make weather tight
by sealing with caulking (not
supplied). Fasten to the chimney
with screws and plugs (not
supplied).
C. INSIDE: Remove the securing
screw from the front of the vent
mounting plate. Pull the vent
mounting plate only, back into
the track, to the front stop. Start
the slider back into position. Re-
secure the screw. The appliance
may now be pushed into its
final position inside the wood
burning appliance, and the screw
tightened until the slider has
been pulled tight to the front stop.
D. Route the flex liners through the slider. Attach and secure the liners to the vent mounting plate using
the same procedure as before, ensuring that the marked exhaust liner is attached to the exhaust
collar.
FLASHING
PLATE
2” (50.8mm)
OVERLAP
SEALANT
HI-TEMP
INTAKE
EXHAUST
SECURING
SCREW
SLIDER
MOUNTING
PLATE
HIGH TEMP
SEALANT
2” (50.8mm)
OVERLAP
3” (76.2mm)
LINERS
EXHAUST
INTAKE
VENT MOUNT
ASSEMBLY
SAFETY BARRIER
3.2 CHIMNEY CONNECTION
Chimney installation must conform to both national and local code requirements. The chimney must be lined
with one 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum and
maximum vent lengths are 10' (3m) and 35' (10m) respectively. Recommended kits come in 3 lengths:
2-3" (50.8mm-76.2mm) DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:
GDI-320KT VENT KIT 20FT
GDI-325KT VENT KIT 25 FT
GDI-335KT VENT KIT 35 FT