B. Remove the 5 screws that secure
the rear log support in place. Lift the
support out.
C. Remove the 4 screws holding the
rear burner tube and lift it up and
out.
D. Remove the 5 screws that secure
the front burner support in place
and lift the support up and out.
E. Remove the 4 screws that secure
the front burner support in place
and lift the burner up and out.
A. Remove the glass door, see "DOOR REMOVAL AND INSTALLATION" section. Remove the
logs, see "FINISHING" section.
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
THE APPLIANCE MAY BE HOT. DO NOT SERVICE APPLIANCE UNTIL IT HAS COOLED.
!
WARNING
ACCESS PLATE
A. To access the fan control module, you must first pull out
the appliance, allowing enough room to access the left
access plate.
B. Remove the screws holding the access plate in position.
C. Unplug the fan control module from the
junction box. Unplug the night light plug and
blower plug (if applicable) from the
fan control module.
D. Remove the 2 screws securing the fan control to
the access plate and replace. NOTE: Ensure
that the ON/OFF switch is in the ON (-) position.
E. Reinstall the plugs and access plate
ON/OFF
SWITCH
8.5 BURNER REMOVAL
8.6 FCM REPLACEMENT