Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of
the small logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed
edges of the fibre hairs will glow. The ember material will only glow when exposed to direct flame;
however, care should be taken to not block the burner ports.
Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZER
TM
logs glow when exposed to direct flame. Use only certified "glowing embers" and PHAZER
TM
logs available
from your authorized dealer / distributor.
97.1A
Remove the backing of the logo supplied and place on the glass viewing
door, as indicated.
½"
(12.7mm)
LOGO
½"
(12.7mm)
Before beginning with the installation, remove the door and all burner media from the appliance including logs
and charcoal strips. Retain the glowing embers.
A. Randomly place the rocks onto the media tray, around, but not on the burner ports or pilot area.
B. Rocks can be carefully stacked. You must ensure that none would fall onto the burner or pilot
while in operation.
C. Turn on gas and electrical supply.
D. Reinstall the glowing embers over the burner.
E. Reinstall the door.
!
WARNING
REAL ROCKS MUST NOT BE USED IN THIS APPLIANCE. HEAT WILL CAUSE THEM TO EXPLODE
4.4 OPTIONAL ROCK PLACEMENT
4.5 GLOWING EMBERS