WATER FILTER
35
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (1.9 lpm)
Water Supply Potable Water
Water Pressure 20-120 psi (138 - 827 kPa)
Water Temperature 33°F - 100°F (0.6°C - 38°C)
It is essential that the manufacturer’s recommended
installation, maintenance and water olter replacement
requirements be carried out for the product to perform as
advertised.
NOTE: While the testing was performed under standard
laboratory conditions, actual performance may vary.
NOTE: To purchase a replacement olter, visit your local
Sears store, or call 1-844-553-6667.
You may also purchase online at www.kenmore.com
Product distributed in the United States by Transform
SR Brands Management LLC, Hoçman Estates, IL 60179
U.S.A.
NSF is a trademark of NSF International.
WARNING
To reduce the risk associated with ingestion of
contaminants: Do not use with water that is
microbiologically unsafe or of unknown Tuality
without adeTuate disinfection before and after the
system Systems certioed for cyst reduction may be
used on disinfected water that may contain olterable
cysts. EPA Establishment Number 10350-MN-005
CAUTION
To reduce the risk associated with property damage
due to water leakage:
v Read and follow the Water Filter instructions before
installation and use of this system.
v Installation and use MUST comply with all state and
local plumbing codes.
v Do not install if water pressure exceeds 120 psi (827
kPa). Contact a plumbing professional if you are
uncertain of how to check your water pressure.
v Do not install where water hammer conditions may
occur. If water hammer conditions exist, you must
install a water hammer arrester. Contact a plumbing
professional if you are uncertain of how to check
for this condition.
v Do not install on hot water supply lines.
The maximum operating water temperature of this
water olter system is 100°F (38°C).
v Protect water olter from freezing Do not operate
refrigerator in ambient conditions below 55°F
(12.7°C). Drain water olter when storing unit in
temperatures below 40°F (4.4°C).
v The disposable water olter must be replaced every
six months, at the rated capacity, or if a noticeable
reduction in pow rate occurs.