Fire Hazard
Usea heavy metal vent.
Do not use a plastic vent.
Do not usea metalfoil vent.
Failureto follow there instructionscan
result in death or fire,
DO Not use non-metal flexible vent or
exhaust hoods with magnetic latches.
Metal exhaust vent must be four inches in
diameter•
Do Not exhaust dryer into a chimney,
furnace, cold air vent, attic or crawl space,
or any other vent used for venting.
DO Not install flexible vent in enclosed
walls, ceilings or floors•
Important: Observe all governing codes and
ordinances.
A dryer must be exhausted outdoors.
Moisture and rint indoors may cause:
Lint to gather around the dryer where it can
de fuel for a fire.
Moisture damage to woodwork, furniture,
paint, wallpaper, carpet, etc.
Housecleaning problems and health problems.
Dura SafeTM venting products are
recommended and are available from your
dealer.
Four-inch diameter vent is required.
Rigid or flexible metal exhaust vent must be
used. Do Not use plastic or metal foil vent.
Rigid metal vent is recommended to prevent
crushing and kinking.
Flexible metal vent must be fully extended and
supported when the dryer is in its final position.
Remove excess flexible vent to avoid sagging
and kinking that may result in reduced airflow.
An exhaust hood should cap the exhaust vent
to prevent rodents and
insectsfrom entering the
home.
Exhaust outlet hood must -- "_.
be at least 12 inches from --
the ground or any obiect --_
that may be in the path of --
the exhaust (such as flowers,
rocks or bushes, etc.)
If using an existing
exhaust system, clean lint from entire length
of system and make sure exhaust hood is not
plugged with lint, Replace any plastic or metal
foil vent with rigid metal or flexible metal vent.
Use clamps to seal all joints. Do Not use duct
tape, screws or other fastening devices that
extend into the interior of the vent to secure
vent.
Service check: Back pressure in any exhaust
system used must not exceed 0.6 inches in
water column measured with an incline
manometer at the point that exhaust vent
connects to dryer.
Mobile homeinstallation
requirements
If codes permit, this appliance is suitable for
mobile home installations. The installation of
the dryer must conform to Manufactured
Home Construction and Safety Standard, Title
24 CFR, Part 3280 (formerly the Federal
Standard for Mobile Homes Construction and
Safety, title 24, HUD Part 280) or latest
edition.
The dryer must be exhausted outside.
wall
floor
elldosed area
The exhaust vent must be securely fastened to
a non-eombus0ble portion of the mobile
home structure and must not terminate
beneath the mobile home.
Plantheexhaustventinstallation
Route the vent
The exhaust exhaust
outlet is located at outlet
the center of the _. _
rear of the dryer.
The exhaust vent can be
routed up, down, left,
right or straight out the
back of the dryer. See
"Recessed area/closet
installation" section,
Panel A, for general
space requirements.
exhaust air flow
better ac_
Select the route that will provide the
straightest and most direct path outdoors.
Plan the installation to use the fewest number of
elbows and turns. Avoid making 90 o turns.
When using elbows or making turns, allow as
much room as possible. Bend vent gradually to
avoid kinking.
Determine ventlength
The maximum length of the exhaust system
depends upon:
-- the type of vent (rigid or flexible metal)•
-- the number of elbows used.
if a combination of rigid and flexible metal
vent is used,
Do not use vent runs longer than specified in
exhaust vent length charts.
Exhaust systems longer than specified will:
Accumulate lint creating a potential fire
hazard•
-- Shorten the lifeof the dryer•
-- Reduce performance, resulting in longer
drying times and increased energy usage.
_4 _ _/_2.tJZ r,
The same length of vent can be used with any
of the three exhaust hoods shown.
Exhaust vent length charts list lengths by type
of vent to be used. Use the chart that matches
your vent type.
When you use
of metal vent...
(_)Determine the number of elbows you will
need.
_)ln the column listing the type of metal vent
you areusing (rigid or flexible), find the
maximum length of metal vent on the
same line asthe number of elbows.
_Number
of 90°
elbows
O
1
2
3
4
$
The_axJmumlem
Maximum length of Rigid metal vent
fully extended Flexible metal vent
4" dia. _ 4" dia.
rigid flexible
metal vent metal vent
120ft 4Oft
11Oft 37ff
100 ft 33 ft
90ft 3Oft
80 ft 27 ft
70 ft 23 ft
Lh ushlg a 2" x 6" rectangular vent with Z
elbows and trallSlllolling into a 2 1/2" exhaust hood Is 8 feel.
When you use a combination of tiaid
and flexible metal vent...
_)Determine the number of elbows you'll need.
(_Determine the length of Flexible metal vent
you'll use. Find the column that has the nearest
number of feet to what you will be using.
_)ln the shaded area of that column find the
maximum length of Rigid metal vent on the
same line as the number of elbows.
Number of Maximum length of fully extended
90" elbows Flexible and Rigid metal vent
_ Length of Flexible metal vent
O' 1-8' 16-I0' 111-15' 116-20'121-25'r
0 20 t 1os 9oft 7s t 6oft
1 10ft" 95ft _Oft ]:d,,S_ ,,,SOft 35ff Length
2 OOft 85_ Yo_ _ft "I0ft 2_ of
3 90ff 75ft :,_ 45ft _ft lSft: Rigid
" ................... _ metal
4 80it 6_f_ 50ff 3$ft 20ft _& vent
s 70f_ $5n 4off 25ff IOf_ 0ft
Example: _)You need to use 2 elbows.
(_You will use 5 feet Flexlble metal
vent.
_)The maximum length of Rlgld
metal vent you can use is 85 feet.