User Manual Smart Electrician TM1627DOLBSE 15-Amp Plug-In 3-Outlet Digital Timer

Documents for Smart Electrician TM1627DOLBSE

The following documents are available:
User Manual Photos
TM1627DOLBSE photo

User Manual

For TM1627DOLBSE.

TM1627DOLBSE
OUTDOOR DIGITAL WEEKLY TIMER
Instruction Manual
RATINGS:
125 Volts 60Hz
15A General Purpose
15A Resistive
8A, 1000W Tungsten
1/2 HP
LCD Display Nomenclature:
Note: Not all functions are available on each timer.
1. AM/PM will appear when 12-hour is set
2. MO to SU stand for Monday, Tuesday, Wednesday, Thursday, Friday, Saturday and Sunday
3. Hour:Minute:Second
4. R will appear when Random mode is enabled
5. Manual/Auto mode.
AUTO OFF, the device is in Timer Mode and remains off until the first ON setting in programs
AUTO ON, the device is in Timer Mode and remains on until the first OFF setting in programs
ON, timer remains on, and will not run any program until override key is pressed and AUTO is
displayed
OFF, timer remains off, and will not run any program until override key is pressed and AUTO is
displayed
6. CTD will appear when countdown is enabled.
7. DST will appear when day light saving enabled
8. D2D will appear when Dusk to Dawn enabled.
9. Program #, up to 20 programs are available
10. ON/OFF indicate the output status
Before using your timer for the first time, please read the instructions carefully.
TM1627DOLB Features
20 programmable ON/OFF settings per week
12 hour AM/PM or 24 hour display
Programmable in 1 minute intervals
Daylight Saving Time setting
Random ON/OFF Feature (2~30 minutes of programmed time)
Dusk to Dawn
Countdown
Manual override – temporarily or permanently overrides current program
Key Functions
SET: Selects and confirms the program setting.
DOWN/UP: Increase or decrease day and digit settings. Also used to enable the Count Down
function by pressing and holding DOWN/UP together.
ON/OFF: Allows user to select On, Off or Auto. Can be used for manual override of timer settings
without losing programming.
D2D: Press D2D to enter D2D mode ,it will turn on at dusk and turn off at dawn. ON/OFF will
indicate the status of current timer output
RND: Press Random ON/OFF setting to activate random delay for start or finish of ON periods.
RESET: Use a pencil or paper clip to press the reset key to initiate programming.
The timer clock must be set before programming any On/Off settings.
Setting the current time
1. If display does not appear, plug unit into a receptacle and charge the internal battery for 1 hour.
2. Remove the unit from the receptacle and press the RESET key to begin programming.
3. Press and hold the ON/OFF key, then press the DOWN key to toggle between 12 or 24 hour
display. AM will appear on the display when 12 Hour display is selected.
4. Press and hold the ON/OFF key, then press the UP key to toggle between normal and Daylight
Savings Time. DST will appear on the display, one hour ahead of the current time. Press the UP key
again to again to cancel DST.
5. Press and hold SET key for 3 seconds ,the “MO” flashes on display, using DOWN or UP keys to
select the current day, press the SET key again to confirm your selection.
6. Hour digits flash on display, using DOWN or UP keys to select current hour, press SET key again to
confirm.
7. Minute digits flash on display, using DOWN or UP keys to select current minute, press SET key again
to confirm. There is no option to set the Seconds.
Note: If programming is interrupted for more than 30 seconds while setting the time, the unit will
automatically revert to default mode. Preset time will be preserved.
Programming priorities are
D2D> Manual ON/OFF>Random>CTD>Programmed events
Dusk to Dawn Function
Press D2D to enter D2D mode ,it will turn on at dusk and turn off at dawn. ON/OFF will indicate the
status of current timer output
Manual Override
The ON/OFF key can be used to switch ON or OFF. Repeated pressing of the ON/OFF key causes
scrolling from AUTO OFF(default)–MANUAL ON–AUTO ON–MANUAL OFF–AUTO OFF.
AUTO OFF, the device is in Timer Mode and remains off until the first ON setting in programs
AUTO ON, the device is in Timer Mode and remains on until the first OFF setting in programs
ON, timer remains on , and will not run any program until override key is pressed and AUTO is
displayed
OFF, timer remains off , and will not run any program until override key is pressed and AUTO is
displayed
Random Function
Turns On after 2-30 minutes of your programmed ON settings, turns Off before 2-30 minutes of your
programmed Off settings . To activate Random Function, press RND button until “R” appear on
display. Press again to cancel. Setting the Random Function will affect all 20 Programs.
Note: Programming of switching times (ON/OFF) will not work properly if ‘program ON’ overlaps with
‘program OFF’
Count Down On/Off Setting
1. Press UP or DOWN key for 3 seconds to enter “CTD” setting interface
2. Press SET key ,OFF flashes on display ,use DOWN or UP keys to select ON or OFF, press SET key to
confirm.
OFF option, keep timer on and turn timer off when CTD finished
ON option, keep timer off and turn timer on when CTD finished.
3. Hour digits flash on display ,Use DOWN or UP keys select hour(s), press SET key to confirm.
4. Minute digits flash on display, using DOWN or UP keys to select minute, press SET key to confirm.
5. Seconds digits flash on display, using DOWN or UP keys to select seconds, press SET key to confirm.
6. Press CTD key to start count down, press CTD key again to stop count down. Timer will keep the
status before CTD stopped.
Note 1: if you are at the current time display, press CTD key ,it will start count down too , CTD on
display will flash and ON/OFF will indicate the status of current timer output
Note 2: If programming is interrupted for more than 30 seconds while setting CTD, unit will
automatically revert to default mode. Preset time will be preserved.
Programming ON/OFF Events (maximum 20 events)
Note: If a programming step is interrupted for more than 30 seconds, unit will automatically revert to
default mode. Press Reset to start the process over.
1. Clock time must be set before programming ON/OFF times.
2. After clock has been set, press the UP key.
3. Press the SET key to edit 1 ON program. Use the UP or DOWN keys to cycle through the days of the
week selections.
Options
1. Individual day of the week
2. MO TU WE TH FR SA SU (Every day)
3. MO TU WE TH FR (Weekdays only)
4. SA SU (Weekends only)
5. MO TU WE TH FR SA
6. MO WE FR
7. TU TH SA
8. MO TU WE
9. TH FR SA
10. MO WE FR SU
Press the SET key again to confirm your selection.
4. Next the Hour digits will flash on the display, use the DOWN or UP keys to select the starting hour.
Press the SET key again to confirm your selection.
5. Next the Minute digits will flash on the display, use the DOWN or UP keys to select the starting
minute. Press the SET key again to confirm your selection.
Next the program 1 OFF setting needs to be programmed.
6. Press UP key to enter 1 OFF editing.
7. Repeat steps 3 thru 5 to set day(s) and enter the day and time the device should turn OFF.
8. To set additional ON/OFF cycles, (maximum 20 events), press UP key. Then press UP or DOWN keys
and follow procedures in steps 3 thru 5 for each new ON/OFF event. When finished, press UP or
DOWN keys to exit , or wait for 1 minute (30 seconds to exit interface of edit timing, 30 seconds to
exit interface of program event)
Note 1: Programming of switching times (ON/OFF) will not work properly if ‘program ON’ overlaps
with ‘program OFF’
Note 2: If programming is interrupted for more than 30 seconds while setting program, unit will
automatically revert to default mode. Preset time will be preserved.
Deleting Programs
1. Press UP key. Use UP or DOWN keys to select ON/OFF event to be deleted.
2. Press ON/OFF key to delete program setting. Press again to restore.
3. When done, press UP or DOWN keys to exit ,or wait for 1 minute (30 seconds to exit interface of
edit timing, 30 seconds to exit interface of program event)
Reset key
Press RESET key. Timer will resume in default status. All time and program information will be lost.
CONFORMS TO UL STD 60730-1, 60730-2-7
CERTIFIED TO CSA STD E60730-1,E730-2-7
Made in China
© 2017
I17-0008-A
3160817