Faucet Cleaning
Turn off the gas supply with the shutoff valve(s) under the
regulator (see Figure 37 or 38) and open the faucet to re-
lieve the pressure. To remove the faucet from the tower use
the spanner wrench provided. Place the pin on the wrench
into the hole on the faucet collar and turn clockwise to
remove the faucet. (See Figure 43).
Remove the knurled cap from the faucet body just below
the handle and pull the handle assembly from the faucet.
This will allow the shaft to be removed from the back of the
faucet, see Figure 44.
Soak all faucet parts in hot clear water or a solution of hot
water and a sanitizing solution. Do not use soap. Rinse
thoroughly with clean water.
Reassemble faucet, assemble faucet to tower (be sure
faucet is in off position), and turn on gas valve.
Figure 43
Figure 44
After removing the
handle the shaft will
slide out the back of the
faucet
Unscrew knurled
cap on faucet body
and remove handle
assembly
Place pin on
wrench into hole
in faucet collar.
CARE AND CLEANING
Keg Coupler Cleaning
Remove the keg coupler from the keg if necessary. Close
the gas valve(s) below the regulator, remove both the red
gas line(s) and clear beer line(s) from the keg coupler(s) by
removing the plastic hose clamps (See Figure 41). Soak
and brush the keg coupler in hot water or a sanitizing solu-
tion. Rinse thoroughly with clean water. Dry all parts and
reassemble.
Cleaning and Maintaining Dispensing System
The dispensing system needs to be cleaned between
usage to prevent spoilage and/or foul taste in your beer.
Figure 42