INSTALLER’S FINAL CHECK LIST
You must test the cooker after installation before you hand it over to the customer. You must
have a manometer and a connecting tube. The following checks have to be made to commission
the cooker and to activate the warranty:
INSTALLATION CHECK
Have the supplied blue washers and fittings been used?
Has a leak test with soapy water been performed?
Is the regulator set for the correct gas type and pressure
Are the jet sizes correct for the gas type?
Is the product earthed & polarity correct to stop flickering of indicator lights?
Has the power cable been checked to ensure it is not touching the product?
Are the burner parts sitting correctly?
OPERATION CHECK
Do all the burners ignite and stay on?
Is the flame blue and appropriately sized?
Does the oven burner ignite and stay on?
Has the oven been operated and been seen to reaching temperature?
Model Number
Date of installation
Name of installer
Signature
License number
SERIAL NUMBER - this is a requirement to request warranty service
GLEM GAS AUSTRALASIA PTY. LTD.
P.O.Box 63 Blaxcell PO South Granville NSW 2142
Phone: 02 96433500 l Fax: 02 96433599 l www.glemgas.com.au
YES NO
YES NO
YES NO
YES NO
YES NO
YES NO
YES NO
YES NO
YES NO
YES NO
YES NO
28