Installation Instructions
USING FLEXNBLE METAL DUCTS
If rigid all-nletal duct cmmot be used, then flexible all-metal
venting cml be used, but it will reduce the maxinmm
rec(_mmended duct length In special installations when it is
impossible to make connection with the above recommendations,
then ULdisted clothes dryer trmlsition duct may be used as
transition venting between the dryer mid wall connection only. The
use of this ducting will affbct dry time.
If flexible transition duct is necessary, the fbllowing directions must
be f_llowed
Use the Shortest Length Possible.
Stretch the Duct to Its Maximum Length
Do Not Crush or Collapse.
Never Use Trmlsition Duct Inside the Wall or
Inside the Dryer.
Avoid Resting the Duct on Sharp Objects.
Venting Must Conf_rm to Local Building Codes.
ELBOWHIGHLY
RECOMMENDED
ELBOWSHIGHLY
DONOTUSE
EXCESSIVE
EXHAUST
LENG
)(
6
[] ALCOVE OR CLOSET NSTALLATION
" If your dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back.
. The dryer MUST be vented to the outdoors. See the
EXHAUST INFORMATION section.
"Minfinum clearance between dryer cabinet and adjacent
walls or other surfaces is:
0 in. either side
3 in. front and rear
° Minimum vertical space from floor to overhead cabinets,
ceiling, etc. is 52 in.
. Closet doors nmst be louvered or otherwise ventilated and
must contain a minimum of 60 sq. in. of open area equally
distributed. If the closet contains both a washer and a
dryer, doors nmst contain a nfininmm of 120 sq. in. of open
area equally distributed.
. The closet should be vented to the outdoors to prevent gas
pocketing in case of a gas leak in the supply line.
. No other flleLburning appliance shMl be installed in the
same closet with the dryer.
[] BATHROOM OR BEDROOM
IN STALLATION
" The dryer MUST be vented to the outdoors. See
EXHAUST INFORMATION section l;.
"The installation nmst confbrm with locM codes or, in the
absence of local codes, with the NATIONAL FUEL GAS
CODE, ANSI Z223.
[] MOBILE OR MANUFACTURED
HOME INSTALLATION
. Installation must conform to the MANUFACTURED
HOME CONSTRUCTION & SAFETY STANDARD,
TITLE 24, PART 32_80 or, when such standard is not
applicable, with AMERICAN NATIONAL SXANDARD
FOR MOBILE HOME, NO. 501B.
The dryer MUST be vented to the outdoors with the
termination securely fastened to the mobile home
structure. (See EXHAUST INFORMATION section 6.)
° The vent MUST NOT be terminated beneath a mobile or
nmnufhcmred home.
The vent duct material MUST BE METAL.
KIT 14-D3All-33 MUST be used to attach the dryer
securely to the structure.
The vent MUST NOT be connected to any other duct,
vent, or chimney.
" Do not use sheet metal screws or other refastening
devices which extend into the interior of the exhaust vent.
*Provide an opening with a fiee area of at least 25 sq in.
fbr introduction of outside air into the dryer room.